Aurora Generators Wildcat RO0045 Roughneck 45 kW NG/LP/VP Prime Power Generator | RO0045NGCSXP - RO0045NGCSXP
Aurora Generators Wildcat RO0045 Roughneck 45 kW NG/LP/VP Prime Power Generator | RO0045NGCSXP - RO0045NGCSXP
Couldn't load pickup availability
Aurora Generators Wildcat RO0045 Roughneck 45 kW NG/LP/VP Prime Power Generator | RO0045NGCSXP - RO0045NGCSXP
Aurora Generators Wildcat RO0045 Roughneck 45 kW NG/LP/VP Prime Power Generator | RO0045NGCSXP - RO0045NGCSXP
-
Model: RO0045NGCSXP
-
Phase/Voltage Options: Includes 3-phase 120/240 V—selectable via dropdown
-
Fuel: Natural Gas (NG), with LPG options
-
Power Output: 45 kW prime (~50 kW max; 62.5 kVA)
-
Engine: Industrial liquid‑cooled Arrow KP3TAC, 1,800 RPM
-
Alternator: Stamford UCI224F — brushless, Class H, auto‑voltage regulation, THD < 5%
-
Controller: Digital DeepSea interface
-
Enclosure: Standard open skid, with Sound Attenuated / Weather Enclosure (Level II) options
What our Experts Think
- Industrial-grade prime power: The Wildcat RO0045 Roughneck delivers 45kW of prime power with approximately 50kW maximum output, making it a dependable solution for commercial facilities, farms, remote sites, and large-scale power applications.
- Flexible fuel capability: Designed for natural gas and LPG operation, this generator provides fuel flexibility for continuous power needs where reliable utility access is limited.
- Built for continuous operation: The Roughneck platform is engineered for 24/7/365 applications, using industrial-grade components designed for demanding prime power environments.
- Premium power quality: A Stamford brushless alternator with automatic voltage regulation and low THD output helps deliver stable electricity for sensitive commercial equipment and critical systems.
- Heavy-duty industrial design: The liquid-cooled Arrow industrial engine, digital DeepSea controller, and rugged construction provide durability, easy monitoring, and dependable long-term performance.
- Professional applications: Ideal for commercial buildings, agriculture, manufacturing, microgrids, remote locations, and mission-critical operations requiring reliable primary power.
- Expert verdict: A premium stationary generator built for organizations that need continuous high-capacity power, fuel flexibility
Q&A
Q: What is the power output of the Wildcat RO0045 Roughneck generator?
A: The Wildcat RO0045 delivers 45kW prime power and up to 50kW maximum output, providing dependable energy for commercial, industrial, and large-scale applications.
Q: What fuel options does the Wildcat RO0045 support?
A: The RO0045 is designed for gaseous fuel operation, supporting natural gas and LPG/propane configurations for flexible power generation.
Q: Is the Wildcat RO0045 suitable for continuous or prime power use?
A: Yes, it is a prime power generator designed for applications requiring reliable long-duration power, including remote sites, microgrids, commercial facilities, and industrial operations.
Q: What engine and alternator does the RO0045 use?
A: It features an industrial liquid-cooled Arrow KP3TAC engine and a Stamford UCI224F brushless alternator with automatic voltage regulation for stable power output.
Q: Is the Wildcat RO0045 a three-phase generator?
A: Yes, the RO0045NGCSXP configuration provides three-phase 120/240V output for commercial and industrial electrical systems.
Q: Does the RO0045 provide clean power for sensitive equipment?
A: Yes, its Stamford alternator delivers regulated power with total harmonic distortion (THD) below 5% to help support modern electrical equipment.
Q: Can the Wildcat RO0045 be installed outdoors?
A: Yes, it is available with weather and sound-attenuated enclosure options for demanding outdoor installations.
Q: Who is the Wildcat RO0045 generator designed for?
A: It is ideal for commercial buildings, agriculture, manufacturing, remote locations, oil and gas operations, and other applications requiring dependable prime power.
Maintenance Tips
- Check engine oil levels regularly and follow the recommended service schedule to maintain reliable prime power operation.
- Replace oil filters and inspect lubrication systems during scheduled maintenance to protect engine components during extended runtime.
- Clean and inspect air intake filters regularly to maintain proper airflow and efficient engine performance.
- Inspect spark plugs, ignition components, and engine controls for reliable starting and continuous operation.
- Check natural gas and LP fuel connections for leaks, secure fittings, and proper fuel pressure before operation.
- Inspect battery condition and connections to ensure dependable automatic starting and control system operation.
- Keep the enclosure, cooling vents, and radiator areas clean to maintain proper airflow and prevent overheating.
- Test digital controller functions and safety alarms regularly to verify monitoring and protection systems are working properly.
- Inspect electrical connections, alternator components, and output voltage during routine service checks.
- Schedule professional preventive maintenance to maximize generator lifespan and maintain dependable prime power performance.