Aurora Generators 70kW Diesel Tier 4 Generator | Multi-Phase Selector - RO0070D4KSXP
Aurora Generators 70kW Diesel Tier 4 Generator | Multi-Phase Selector - RO0070D4KSXP
Couldn't load pickup availability
Aurora Generators 70kW Diesel Tier 4 Generator | Multi-Phase Selector - RO0070D4KSXP
Aurora Generators 70kW Diesel Tier 4 Generator | Multi-Phase Selector - RO0070D4KSXP
-
70 kW Prime Rated Output – Delivers 87 kVA (3-phase) or 63 kW (single-phase) at 0.8 PF
-
DOOSAN DM03PP Tier 4 Final Engine – Liquid-cooled, efficient, and EPA-compliant industrial power source
-
STAMFORD UCI224G Alternator – Brushless alternator engineered for heavy-duty and clean energy output
-
DEEPSEA Digital Controller – Integrated system controls with auto-start, synchronization, and advanced diagnostics
-
Multi-Phase Selector (1P/3P) – Easy switching between single- and three-phase output configurations
-
Sound/Weather Level II Enclosure – UL‑2200 certified for acoustic and environmental protection
-
Stationary Setup – Designed for fixed applications with 24-hour operational capability
What our Experts Think
- Industrial-grade power solution: The Aurora Generators 70kW Diesel Tier 4 Generator is designed for demanding commercial, construction, agricultural, and critical power applications requiring dependable long-term performance.
- Flexible multi-phase capability: The built-in multi-phase selector allows users to switch between single-phase and three-phase power, providing greater versatility across different job sites and equipment requirements.
- Efficient Tier 4 diesel performance: The Tier 4 Final diesel engine delivers reliable power while meeting modern emissions standards, making it a strong choice for professional applications.
- Built for continuous operation: Experts appreciate features such as extended fuel capacity, rugged enclosure protection, and durable components designed for demanding environments.
- Advanced monitoring and control: The digital controller provides operational insights, diagnostics, and protection features to help simplify maintenance and improve reliability.
- Best suited for: Construction sites, industrial facilities, emergency backup systems, remote locations, utilities, and applications requiring flexible high-output diesel power.
Q&A
Q: What is the Aurora Generators 70kW Diesel Tier 4 Generator | Multi-Phase Selector (RO0070D4KSXP)?
A: A commercial-grade diesel generator designed for industrial, construction, agricultural, and backup power applications requiring reliable high-capacity electricity and flexible phase operation.
Q: How much power does the RO0070D4KSXP provide?
A: It delivers 70kW prime power output and is built for demanding applications requiring dependable continuous power.
Q: What does the Multi-Phase Selector feature do?
A: It allows users to switch between single-phase and three-phase power, providing flexibility for different equipment and electrical systems.
Q: Is this generator Tier 4 compliant?
A: Yes. It uses a Tier 4 Final diesel engine designed to meet strict emissions requirements while maintaining efficient operation.
Q: What engine and alternator does it use?
A: The unit features a Doosan DM03PP Tier 4 Final diesel engine and a Stamford UCI224G brushless alternator for stable, industrial-grade power delivery.
Q: Is this generator suitable for commercial backup power?
A: Yes. It is designed for commercial facilities, remote sites, utilities, construction projects, and other applications needing reliable high-output power.
Q: Does it include smart monitoring and protection features?
A: Yes. The generator includes a digital controller with automatic start/stop, diagnostics, and protection functions for easier operation and maintenance.
Q: Who is the RO0070D4KSXP best for?
A: It is ideal for businesses, industrial operations, contractors, farms, and critical facilities requiring versatile and dependable diesel power.
Q: Why choose a 70kW diesel generator?
A: A 70kW diesel generator provides robust backup and prime power capability for large equipment, facilities, and operations where consistent electricity is essential.
Maintenance Tips
- Check engine oil, coolant, and diesel fuel levels regularly before operation.
- Follow scheduled service intervals for oil changes, filters, and fluid replacements to maintain reliability.
- Inspect and replace air, fuel, and oil filters as needed to support efficient engine performance.
- Keep the generator enclosure, cooling system, and air intake areas clean and free from dust or debris.
- Inspect battery connections, terminals, and charging system regularly to ensure dependable starts.
- Check fuel lines, hoses, belts, and electrical connections for leaks, wear, or damage.
- Monitor the Tier 4 emission system and maintain required components to support emissions compliance.
- Run periodic operational tests under proper load conditions to confirm performance and prevent downtime.
- Keep the multi-phase selector, control panel, and electrical components clean and protected from moisture.
- Store maintenance records and follow the manufacturer’s recommended service schedule for long-term reliability.