Goodman - 80,000 BTU 80% Variable Speed Gas Furnace - 21" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GRVT800804CN
Goodman - 80,000 BTU 80% Variable Speed Gas Furnace - 21" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GRVT800804CN
Couldn't load pickup availability
Goodman - 80,000 BTU 80% Variable Speed Gas Furnace - 21" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GRVT800804CN
Goodman - 80,000 BTU 80% Variable Speed Gas Furnace - 21" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GRVT800804CN
The GRVT800804CN gas furnace is from one of the top-of-the-line series by Goodman. Considered one of the best of the best, this furnace has a two stage burner and a variable speed blower motor. With the best durability and reliability that Goodman 80% efficient furnaces have to offer, we are proud to offer you the Goodman GRVT800804CN gas furnace.
Features
- This furnace is ideal to heat a small to medium house (in average climate conditions)
- 80,000 BTU 80% AFUE two stage variable speed natural gas furnace
- Requires metal flue venting
- Can be used in the upflow or horizontal orientation
- Can be converted to propane with an LP conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
Specifications
| SKU | GRVT800804CN |
|---|---|
| Weight (in lbs) | 118.000000 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| R-32 Compliant | Yes |
| Brand/Manufacturer | Goodman |
| Product Features | New Refrigerant Compliant |
| Furnace Efficiency / AFUE | 80% |
| Heating BTU | 80,000 |
| Blower Motor | Variable Speed |
| Maximum CFM | 1600 |
| Configuration | Upflow/Horizontal |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 33 3/8" |
| Width | 21" |
| Depth | 28" |
| Warranty | Lifetime Heat Exchanger, 10 Years Unit Replacement, and 10 Years Parts with Online Registration |
| Tonnage | 2.5 Ton |
| Connection | Sweat |
| Height | 32" |
| Width | 29" |
| Depth | 29" |
Owner's Manual
What our Experts Think
-
Variable‑Speed Comfort Control
• The variable‑speed blower motor continuously adjusts airflow to match demand, improving temperature consistency, quieter operation, and better air circulation compared with single‑stage units. -
Two‑Stage Heating Performance
• With two heating stages, the furnace runs at lower capacity for mild days and full power when it’s cold, reducing cycling and enhancing comfort. -
Good Seasonal Efficiency
• 80% AFUE provides solid heating performance at an affordable price point — a dependable choice for moderate climates. -
Flexible Installation Options
• Designed for upflow or horizontal configurations, making it suitable for attic, closet, or crawl‑space setups where space constraints matter. -
Standard 115 V Operation
• Uses everyday 115‑volt power, simplifying electrical connections during installation. -
R‑32 System Compatibility
• While the furnace itself doesn’t use refrigerant, pairing it with R‑32 air conditioning equipment supports modern efficiency goals and environmental performance.
Q&A
Q: What heating capacity does this furnace provide?
A: This unit delivers 80,000 BTU of heating output, ideal for medium homes and residential spaces.
Q: How efficient is this furnace?
A: It operates at 80% AFUE, converting 80% of fuel into heat for reliable, cost‑effective performance.
Q: What type of blower and staging does it have?
A: Features a variable‑speed ECM blower and two‑stage gas valve for smoother temperature control, quieter operation, and improved airflow.
Q: What installation orientations are supported?
A: Supports both upflow and horizontal installation, offering flexibility for basements, attics, closets, or crawlspaces.
Q: What fuel and power requirements are needed?
A: Runs on natural gas (propane convertible) and uses 115 V electrical power.
Q: Is this model environmentally compliant?
A: Designed for standard emissions compliance and paired with R‑32 compatible systems in matched installations.
Q: Does it support advanced diagnostics or smart thermostats?
A: Compatible with ComfortBridge™ enabled controls and most modern thermostats for optimized performance.
Maintenance Tips
-
Replace or Clean Air Filters
Inspect monthly; replace every 1–3 months to maintain airflow and energy efficiency. -
Inspect Burner and Heat Exchanger
Annual professional inspection ensures safe operation and proper 80% AFUE performance. -
Clean Blower and Fan Assembly
Dust buildup reduces airflow and efficiency; schedule annual cleaning. -
Check Thermostat Operation
Ensure proper calibration and smooth operation of the two-stage system. -
Maintain Ductwork and Vents
Clear obstructions in upflow or horizontal configurations for even heating. -
Inspect Electrical Connections
Verify wiring is secure; have a technician check for wear or corrosion during yearly service. -
Schedule Annual Professional Maintenance
Technician should check gas pressure, blower performance, and safety controls to extend furnace life.