Goodman - 60,000 BTU 96% Gas Furnace - 17.5" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GR9T960603BN
Goodman - 60,000 BTU 96% Gas Furnace - 17.5" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GR9T960603BN
Couldn't load pickup availability
Goodman - 60,000 BTU 96% Gas Furnace - 17.5" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GR9T960603BN
Goodman - 60,000 BTU 96% Gas Furnace - 17.5" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GR9T960603BN
As a high-efficiency system, the GR9T960603BN Goodman gas furnace features many money saving features. The two-stage, 9-speed furnace uses a superior heat exchanger for better heat transfers to your home. Considered one of the best efficiencies on the market, the GR9T960603BN is a good way to go if you want to lower your gas bill.
Features
- This furnace is ideal to heat a medium-sized house (depending on climate)
- 60,000 BTU 96% AFUE natural gas furnace
- Requires plastic/PVC flue venting
- Complies with Clean Air Act New Refrigerant Requirements
- Can be used in the upflow or horizontal orientation
- Can be converted to an LP furnace with an optional conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
Specifications
| Goodman 96% 60,000 BTU Two Stage Gas Furnace - 17.5" Width - Upflow / Horizontal | |
|---|---|
| SKU | GR9T960603BN |
| Weight (in lbs) | 115.000000 |
| AHRI Certificate Number | 215225026 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| R-32 Compliant | Yes |
| Brand/Manufacturer | Goodman |
| Product Features | New Refrigerant Compliant |
| Furnace Efficiency / AFUE | 96% |
| Heating BTU | 60,000 |
| Blower Motor | 9 Speed - ECM |
| Maximum CFM | 1200 |
| Configuration | Upflow/Horizontal |
| Energy Star | Yes |
| Electrical | 115 V. 1 Phase 60 Hz |
| Max Breaker Size | 15 Amps |
| Min. Breaker Size | 7.8 Amps |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
Manual
What our Experts Think
-
High‑Efficiency Performance You Can Feel
The Goodman GD9S961005CN 100,000 BTU Gas Furnace delivers 96 % AFUE heating—meaning most of the fuel becomes usable heat, helping reduce utility costs and carbon waste compared to lower‑efficiency models. -
Consistent Comfort with Single‑Stage Heat
A single‑stage gas valve ensures reliable, steady heat whenever called for—ideal for homeowners who want straightforward, dependable warmth without modulation complexity. -
Quiet, Efficient Airflow with Multi‑Speed Blower
The 9‑speed ECM blower motor provides smoother airflow control, quieter circulation, and more efficient electricity use than traditional blower motors. -
Durable Construction & Advanced Controls
Features like a heavy‑duty aluminized‑steel heat exchanger, stainless secondary heat exchanger, durable silicon nitride igniter, and self‑diagnostic control board boost reliability and make maintenance easier for technicians. -
Flexible Downflow/Horizontal Installation
Designed for downflow or horizontal airflow setups, this furnace fits into tight attic or utility spaces while offering PVC/plastic flue venting compatibility and multiple service access points. -
Built for Modern R‑32 System Integration
Compatible with R‑32 refrigerant‑ready HVAC layouts, it pairs well with newer evaporator coils and air conditioners designed for next‑generation system performance.
Q&A
Q1: What heating capacity and efficiency does this furnace deliver?
A: The Goodman GD9S961005CN delivers 100,000 BTU input with 96% AFUE, converting most fuel into heat for higher energy efficiency and lower heating costs.
Q2: What installation orientations are supported?
A: It supports downflow and horizontal installation, offering flexible placement in attics, crawl spaces, or closets.
Q3: What type of blower and motor does it use?
A: This model includes a multi‑speed ECM blower motor for smoother airflow and quieter operation.
Q4: What gas valve and operation style does it have?
A: It features a single‑stage gas valve for reliable, economical heat output.
Q5: What construction and durability features are included?
A: Standard features include a heavy‑gauge steel cabinet, aluminized steel primary heat exchanger, stainless‑steel secondary heat exchanger, durable hot surface igniter, and self‑diagnostic control board for long‑lasting performance.
Q6: What electrical and venting requirements apply?
A: The furnace runs on 115 V single‑phase power and uses PVC/plastic venting typical of high‑efficiency furnaces.
Q7: What are the physical dimensions?
A: Its cabinet dimensions are about 21″ W × 28.75″ D × 34.5″ H, making it compact for standard HVAC spaces.
Q8: Is it compatible with modern refrigerant systems?
A: Yes — it’s compliant with R‑32 refrigerant system integration when paired with matched cooling equipment.
Maintenance Tips
-
Replace Air Filters Every 1–3 Months – Clean filters keep airflow strong, protect the blower, and reduce strain on combustion components.
-
Annual Professional Inspection – A certified HVAC tech should check and clean burners, heat exchanger, ignition system, and PVC flue venting to maintain the 96% AFUE efficiency and safety.
-
Clean Condensate Drain & Vent Pipes – High‑efficiency furnaces produce condensate; flush drain lines seasonally and ensure PVC intake/exhaust pipes are clear of debris or blockages.
-
Inspect Electrical & Control Components – Periodically check wiring, limit switches, and the self‑diagnostic control board for secure connections and proper operation.
-
Maintain Clear Airflow – Keep supply/return vents unobstructed and the area around the furnace free of dust and flammable items to support efficient performance.
-
Test Thermostat & Safety Devices – Replace thermostat batteries yearly and test carbon monoxide detectors regularly for safe operation.
-
Record All Maintenance – Track filter changes, inspections, and service visits to support warranty coverage and long‑term performance.