Goodman - 5 Ton/60,000 BTU - Multi-Positional - Heat Pump Split System - 16 SEER2 - R32 - GLZS5BA6010
Goodman - 5 Ton/60,000 BTU - Multi-Positional - Heat Pump Split System - 16 SEER2 - R32 - GLZS5BA6010
Couldn't load pickup availability
Goodman - 5 Ton/60,000 BTU - Multi-Positional - Heat Pump Split System - 16 SEER2 - R32 - GLZS5BA6010
Goodman - 5 Ton/60,000 BTU - Multi-Positional - Heat Pump Split System - 16 SEER2 - R32 - GLZS5BA6010
The Goodman Heat Pump Split System is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, the Goodman Heat Pump Split System is a perfect choice for all of your heating and cooling needs.
Features
- Designed to cover a smaller house in average climates
- 5 Ton, 15.2 SEER2 heat pump condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed bi-flow filter drier
-
Air Handler
- 5 ton air handler
- Electric heat compatible
- Optimized for use with R-32 refrigerant
- Multi-speed, direct drive ECM blower motor
- Multi-positional (upflow, downflow, or horizontal)
Specifications
| 5 Ton 15.2 SEER2 High Efficiency Goodman Heat Pump - 7.8 HSPF2 | |
|---|---|
| SKU | GLZS5BA6010 |
| Weight | 329.000000 |
| Manufacturer | Goodman |
| Replaces | GSZ160601 |
| Cooling BTU | 60,000 |
| Heating BTU | 60,000 |
| Blower Motor | Single Speed Motor |
| Decibel Level (dBA) | 76 |
| Horsepower | 0.2 HP |
| Refrigerant | R32 |
| SEER2 | 15.2 |
| Condenser Stages | Two Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Electrical | 208/230v 1 Phase 60Hz |
| Max Breaker Size | 50 Amps |
| Min. Breaker Size | 33.0 Amps |
| Tonnage | 5 Ton |
| Connection | Sweat |
| Height | 41 5/8" |
| Width | 35 1/2" |
| Depth | 35 1/2" |
Manual
- GSZH5 Installation Manual
- GSZH5 Specifications Sheet
- AMST Installation Manual
- AMST Specifications Sheet
What our Experts Think
-
Robust 5‑Ton Heating & Cooling: Provides 60,000 BTU capacity for year‑round comfort in medium to larger homes, delivering dependable cooling and heat pump operation in a single system.
-
High Efficiency (16 SEER2 / 8.2 HSPF2): 16 SEER2 rating helps lower energy bills and improve efficiency compared to lower‑SEER systems, without the premium cost of variable‑speed models.
-
Single‑Stage Scroll Compressor: A single‑stage compressor focuses on reliability and simplicity—ideal for homeowners and property managers who want dependable performance with fewer moving parts.
-
R‑32 Refrigerant Ready: Uses R‑32 refrigerant, which improves heat‑transfer efficiency and reduces environmental impact compared to older refrigerants.
-
Durable Outdoor Construction: Heavy‑gauge galvanized‑steel cabinet with powder‑coat finish and protective coil guard stand up to weather and outdoor conditions for long‑lasting durability.
-
SmartShift® Defrost Control: Includes reliable defrost control for smoother heating cycles and reduced noise during winter operation.
-
Service‑Friendly Features: Factory‑installed service valves, high/low pressure switches, crankcase heater, muffler, and easy‑access gauge ports support faster maintenance and improved system protection.
Q&A
Q: What heating and cooling capacity does the Goodman GLZS5BA6010 split system provide?
A: The Goodman GLZS5BA6010 delivers 5 tons (≈60,000 BTU) of both cooling and heating capacity, making it well‑suited for larger homes or whole‑house HVAC systems.
Q: What efficiency ratings does this heat pump achieve?
A: It offers up to 16 SEER2 cooling efficiency and about 8.2 HSPF2 heating efficiency, helping lower energy use and utility costs.
Q: What type of refrigerant and compressor does it use?
A: The unit uses environmentally friendly R‑32 refrigerant and a single‑stage scroll compressor for reliable year‑round performance.
Q: Is this system multi‑positional?
A: Yes — the air handler is multi‑positional (upflow, downflow, or horizontal), offering flexible installation in attics, basements, or closets.
Q: What built‑in features support durability and maintenance?
A: Includes factory‑installed filter drier, suction‑line accumulator, crankcase heater, service valves with easy gauge access, pressure safety switches, and extended‑life capacitors, plus a heavy‑gauge galvanized‑steel cabinet.
Q: What electrical and connection specs are typical?
A: Operates on 208/230 V single‑phase power, with standard ⅜″ liquid and 1 1/8″ suction line connections and pre‑charge for up to ~15 ft of line set.
Maintenance Tips
-
Maintain at least 24 inches of clearance around the outdoor condenser for proper airflow and efficient operation.
-
Clean condenser and evaporator coils regularly with low-pressure water to maintain SEER2 16 efficiency.
-
Replace or clean indoor air filters every 1–3 months to reduce strain on the compressor and maintain airflow.
-
Inspect refrigerant lines and insulation for leaks, damage, or loose connections to ensure optimal R‑32 performance.
-
Check electrical connections and disconnect box for wear, corrosion, or loose wiring.
-
Monitor unusual noises or vibrations from the compressor, fan, or system components as early indicators of maintenance needs.
-
Ensure the unit is level to prevent drainage issues and uneven cooling/heating.
-
Keep the cabinet and coil guards clean and intact to protect components and maintain airflow.
-
Schedule annual professional HVAC service to inspect refrigerant charge, coils, and system controls.