Replace or clean air filters every 1–3 months to maintain proper airflow and prevent dust buildup on the coil.
-
Inspect and clean the evaporator coil annually to ensure efficient heat transfer and consistent cooling performance.
-
Keep the condensate drain pan and drain line clear to prevent water overflow, clogs, and mold growth.
-
Check refrigerant line connections (3/8" liquid, 7/8" suction) for leaks or damaged insulation.
-
Verify TXV (thermal expansion valve) operation for correct refrigerant flow and system efficiency.
-
Inspect coil cabinet and insulation to prevent air leaks and condensation issues.
-
Maintain a clean surrounding area to reduce dust and moisture near the unit.
-
Schedule annual professional HVAC maintenance to check coil condition, refrigerant charge, and overall system performance.
Goodman - 5 Ton/60,000 BTU - Multi-Positional - Heat Pump Split System - 14.5 SEER2 - R32 - GLZS4BA6010
Goodman - 5 Ton/60,000 BTU - Multi-Positional - Heat Pump Split System - 14.5 SEER2 - R32 - GLZS4BA6010
Couldn't load pickup availability
Goodman - 5 Ton/60,000 BTU - Multi-Positional - Heat Pump Split System - 14.5 SEER2 - R32 - GLZS4BA6010
Goodman - 5 Ton/60,000 BTU - Multi-Positional - Heat Pump Split System - 14.5 SEER2 - R32 - GLZS4BA6010
The Goodman Heat Pump Split System is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, the Goodman Heat Pump Split System is a perfect choice for all of your heating and cooling needs.
Features
- Ideal size to cover a smaller house in ideal climates
- 5 ton, 14.3 SEER2 heat pump condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed bi-flow filter drier
-
Air Handler
- 5 ton air handler
- Electric heat compatible
- Optimized for use with R-32 refrigerant
- Multi-speed, direct drive ECM blower motor
- Multi-positional (upflow, downflow, or horizontal)
Specifications
| 5 Ton 14.3 SEER2 Goodman Heat Pump - R32 | |
|---|---|
| SKU | GLZS4BA6010 |
| Weight | 320.000000 |
| Manufacturer | Goodman |
| Replaces | GSZ140601, GSZB406010 |
| HSPF2 | 7.8 |
| Cooling BTU | 60,000 |
| Heating BTU | 60,000 |
| Blower Motor | Single Speed PSC Motor |
| Decibel Level (dBA) | 75 |
| Horsepower | 1/4 HP |
| Refrigerant | R32 |
| SEER2 | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Electrical | 208/230v 1 Phase 60 Hz |
| Max Breaker Size | 50 Amps |
| Min. Breaker Size | 31.1 Amps |
| Tonnage | 5 Ton |
| Connection | Sweat |
| Height | 41 3/4" |
| Width | 35 1/2" |
| Depth | 35 1/2" |
Manual
- GLZS4B Installation Manual
-
GLZS4B Specifications Sheet
- AMST Installation Manual
-
AMST Specifications Sheet
What our Experts Think
-
Robust 5‑Ton Heating & Cooling: Provides 60,000 BTU capacity for year‑round comfort in medium to larger homes, delivering dependable cooling and heat pump operation in a single system.
-
High Efficiency (16 SEER2 / 8.2 HSPF2): 16 SEER2 rating helps lower energy bills and improve efficiency compared to lower‑SEER systems, without the premium cost of variable‑speed models.
-
Single‑Stage Scroll Compressor: A single‑stage compressor focuses on reliability and simplicity—ideal for homeowners and property managers who want dependable performance with fewer moving parts.
-
R‑32 Refrigerant Ready: Uses R‑32 refrigerant, which improves heat‑transfer efficiency and reduces environmental impact compared to older refrigerants.
-
Durable Outdoor Construction: Heavy‑gauge galvanized‑steel cabinet with powder‑coat finish and protective coil guard stand up to weather and outdoor conditions for long‑lasting durability.
-
SmartShift® Defrost Control: Includes reliable defrost control for smoother heating cycles and reduced noise during winter operation.
-
Service‑Friendly Features: Factory‑installed service valves, high/low pressure switches, crankcase heater, muffler, and easy‑access gauge ports support faster maintenance and improved system protection.
-
Multi‑Positional Installation Ready: Pairs well with compatible multi‑positional air handlers for flexible upflow/downflow/side‑flow configurations to suit various duct layouts.
Q&A
Q: What size and application is the Goodman CHPTA3630C3 coil?
A: The Goodman CHPTA3630C3 is a 3 ton horizontal cased evaporator coil designed for residential HVAC split systems needing efficient indoor heat exchange.
Q: What refrigerant does this evaporator coil support?
A: It’s optimized specifically for R‑32 refrigerant, meeting modern efficiency and environmental standards.
Q: Does this coil include a metering device?
A: Yes — it comes with a factory‑installed thermal expansion valve (TXV) for accurate refrigerant flow control in cooling or heat pump applications.
Q: What are the key construction features?
A: Features all‑aluminum evaporator coil, galvanized steel cased cabinet with foil‑faced insulation, and rust‑resistant, UV‑protected thermoplastic drain pans designed for durability and easy maintenance.
Q: What are the physical specifications?
A: Cabinet measures about 30″ W × 21″ H × 21″ D, with 3/8″ liquid and 7/8″ suction line connections for standard residential HVAC installs.
Q: Is this coil certified and safe?
A: Yes — the CHPTA3630C3 is AHRI certified and ETL listed for tested performance and safety compliance.
Q: What installation orientation is supported?
A: Built for horizontal installation, making it suitable for attic, crawlspace, or sideways airflow applications.
Maintenance Tips