Goodman - 5 Ton/60,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA6010
Goodman - 5 Ton/60,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA6010
Couldn't load pickup availability
Goodman - 5 Ton/60,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA6010
Goodman - 5 Ton/60,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA6010
The Goodman GLZS4BA6010 heat pump condenser is a standard efficiency, low-cost solution for an all-electric home when paired with a suitable heat pump coil or air handler. Just like all of Goodman's equipment, the GLZS4BA6010 is manufactured with high-quality materials to provide a superior comfort in your home.
Features
- Ideal size to cover a smaller house in ideal climates
- 5 ton, 14.3 SEER2 heat pump condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed bi-flow filter drier
Specifications
| SKU | GLZS4BA6010 |
|---|---|
| Weight (in lbs) | 320.000000 |
| Brand/Manufacturer | Goodman |
| Replaces | GSZ140601, GSZB406010 |
| HSPF2 | 7.8 |
| Cooling BTU | 60,000 |
| Heating BTU | 60,000 |
| Blower Motor | Single Speed PSC Motor |
| Decibel Level (dBA) | 75 |
| Horsepower | 1/4 HP |
| Refrigerant | R32 |
| SEER2 (Efficiency) | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Electrical | 208/230v 1 Phase 60 Hz |
| Max Breaker Size | 50 Amps |
| Min. Breaker Size | 31.1 Amps |
| Tonnage | 5 Ton |
| Connection | Sweat |
| Height | 41 3/4" |
| Width | 35 1/2" |
| Depth | 35 1/2" |
Manual
What our Experts Think
-
Balanced Heating & Cooling Performance
This 5‑ton heat pump condenser delivers 60,000 BTU in both cooling and heating, making it well‑suited for whole‑home comfort in moderate to mixed climates. -
Efficient 14.3 SEER2 Rating
The 14.3 SEER2 score provides solid seasonal energy efficiency, helping lower utility costs without a premium price tag. -
Single‑Stage Scroll Compressor
A single‑stage scroll compressor offers dependable, straightforward operation with quiet and reliable performance throughout the seasons. -
Modern R‑32 Refrigerant Design
Built for R‑32 refrigerant, this unit supports improved environmental performance and modern HVAC compliance. -
Durable Heavy‑Duty Construction
Features like a galvanized steel cabinet with powder‑coat finish and coil guard protect internal components from corrosion and weather, extending longevity. -
SmartShift & Built‑In Protection
Includes SmartShift defrost technology, high/low pressure switches, and factory‑installed filter driers to increase system reliability and reduce wear from frost or contaminants. -
Installer‑Friendly Service Access
Sweat‑connection service valves, accessible gauge ports, and a fully enclosed contactor make installation and maintenance more efficient. -
Quiet Yet Powerful Operation
Designed to operate around 75 dBA, this unit balances power and sound levels to keep outdoor noise reasonable.
Q&A
Q: What cooling and heating capacity does this heat pump deliver?
A: This unit provides 60,000 BTU (5 tons) of both cooling and heat — ideal for large homes or full‑system HVAC replacements.
Q: How energy efficient is it?
A: It features a 14.3 SEER2 rating and an HSPF2 around 7.8, offering reliable year‑round comfort with solid efficiency under current standards.
Q: What refrigerant does this unit use?
A: Uses environmentally friendly R‑32 refrigerant, which has lower global warming potential (GWP) compared to older refrigerants.
Q: What type of compressor is included?
A: Equipped with a single‑stage scroll compressor for dependable, straightforward performance.
Q: What electrical requirements are needed?
A: Operates on 208/230 V single‑phase, 60 Hz power, with standard circuit protection.
Q: How loud is the unit during operation?
A: Typical sound level is about 75 dB, comparable to most residential outdoor heat pumps.
Q: Is this unit easy to service and install?
A: Yes — it has sweat connections, easy‑access service valves, and factory‑installed protections like suction‑line accumulators and crankcase heaters.
Maintenance Tips
-
Clean the outdoor condenser coil regularly to remove dirt, leaves, and debris that reduce efficiency.
-
Maintain 2–3 feet of clearance around the unit for proper airflow.
-
Replace or clean indoor air filters every 1–3 months to maintain airflow and system performance.
-
Inspect refrigerant lines and insulation for damage or wear.
-
Keep the condenser fan and top grille clear of debris to prevent airflow restriction.
-
Check the condensate drain line periodically to avoid clogs and water damage.
-
Ensure thermostat is working properly and set for efficient heating/cooling cycles.
-
Listen for unusual noises like rattling, buzzing, or squealing, which may indicate mechanical issues.
-
After storms or high winds, inspect the outdoor unit for debris or damage.
-
Schedule annual professional HVAC maintenance to inspect refrigerant levels, electrical components, and overall system performance.
