Goodman - 4 Ton/80,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM34808031
Goodman - 4 Ton/80,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM34808031
Couldn't load pickup availability
Goodman - 4 Ton/80,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM34808031
Goodman - 4 Ton/80,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM34808031
The Goodman GPGM34808031 is a gas heat and electric AC packaged unit, ready for any application where it is not convenient to have an indoor furnace or air handler. At 13.4 SEER2 and 80% AFUE, the GPGM34808031 is an inexpensive option with a standard efficiency designed for rooftop and next-to-building applications.
Features
- 4 ton, 80,000 BTU packaged unit
- 13.4 SEER2, 80% AFUE
- Downflow or horizontal discharge installation options
- Fully charged and ready to install
- Low sound output
- Low NOx compliant
Specifications
| 4 Ton 13.4 SEER2 80,000 BTU Goodman Gas Packaged Unit - R32 | |
|---|---|
| SKU | GPGM34808031 |
| Weight (in lbs) | 523.000000 |
| AHRI Certificate Number | 209319544 |
| Brand/Manufacturer | Goodman |
| Replaces | GPU1448080M41, GPG1448080M41 |
| Furnace Efficiency / AFUE | 80% |
| Cooling BTU | 46,500 BTU |
| Heating BTU | 80,000 BTU |
| Blower Motor | Multi-Speed |
| Maximum CFM | 1525 |
| Decibel Level (dBA) | 78 decibels |
| Configuration | Downflow/Horizontal |
| Refrigerant | R32 |
| SEER2 (Efficiency) | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size | 50 amps |
| Tonnage | 4 Ton |
| Fuel Type | Natural Gas |
| Height | 42 1/2" |
| Width | 47" |
| Depth | 51" |
Manual
- GPGM3 Specifications Sheet
- GPGM3 Installation Manual
- GPGM3 Replacement Parts Manual
-
GPGM3 Service Manual
What our Experts Think
-
All‑in‑One Heating & Cooling Solution
The Goodman GPGM34808031 is a 4 Ton, 80,000 BTU gas‑electric packaged HVAC system featuring both heating and cooling in one outdoor unit—ideal where indoor furnace/air handler space is limited. -
Balanced Comfort with Standard Efficiency
With 13.4 SEER2 cooling and ~80–81 % AFUE heating, it delivers seasonal cooling efficiency and dependable gas heat performance that meets national performance baselines. -
R‑32 Refrigerant for Better Environmental Impact
Factory‑charged with R‑32 refrigerant, it supports modern HVAC regulatory trends and lower global warming potential than older refrigerants without sacrificing performance. -
Versatile Installation Options
A downflow/horizontal airflow design lets technicians adapt the unit to roof‑mounted or ground‑level setups, adding flexibility for different home layouts. -
Dependable Components Inside
Featuring a single‑stage scroll compressor, multi‑speed ECM blower motor, and heavy‑gauge steel cabinet with sound‑insulation, this unit promotes steady airflow, durability, and quieter operation. -
Low NOx Compliance & Weather‑Ready Build
Built to meet Low NOx emission standards and crafted with corrosion‑resistant steel construction, it’s suited for rooftop or outdoor installations in diverse climates. -
Installer‑Friendly & Ready to Go
Comes factory‑charged and pre‑configured, reducing setup time for HVAC pros and helping ensure smooth installation and startup.
Q&A
Q1: What type of HVAC unit is this?
A: The Goodman GPGM34808031 is a 4 ton gas‑electric packaged HVAC system that combines both cooling and heating in one outdoor unit — no separate indoor furnace or coil required.
Q2: What are the heating and cooling capacities?
A: It delivers 80,000 BTU of natural gas heating and 4 tons (~46,000 BTU) of cooling capacity in a single packaged system for year‑round comfort.
Q3: What efficiency ratings does it have?
A: This unit offers 13.4 SEER2 cooling efficiency and approximately 80–81% AFUE heating efficiency, balancing performance with cost‑effective operation.
Q4: Which refrigerant is used?
A: The packaged unit is factory‑charged with R‑32 refrigerant, a modern, lower‑environmental‑impact choice for residential cooling.
Q5: How is airflow configured?
A: It supports downflow or horizontal discharge airflow, giving flexibility for different rooftop or outdoor installations.
Q6: What kind of compressor and motor does it use?
A: A single‑stage scroll compressor provides reliable cooling start‑to‑finish, paired with a multi‑speed ECM blower motor for balanced air delivery and improved comfort.
Q7: What are its key construction and sound features?
A: Built with a heavy‑gauge steel cabinet and sound‑insulated panels, it’s designed for quiet outdoor operation and durability in varied climates.
Q8: What electrical and installation specs should I know?
A: The unit runs on 208/230 V single‑phase power, typically requiring up to a 50 A breaker. It’s fully charged and ready for installation with minimal setup time.
Maintenance Tips
-
Change or Clean Air Filters Every 1–3 Months – Accessible filters protect internal coils and blower motors, keeping airflow strong and reducing energy costs.
-
Clean Evaporator & Condenser Coils Annually – Dust buildup on the all‑aluminum coil lowers heat transfer and SEER2 efficiency; professional cleaning preserves performance.
-
Inspect Condensate Drain & Pan – Clear the drain line to prevent water buildup and mold growth, especially in cooling seasons.
-
Check Electrical Connections & Controls – Tighten loose terminals, inspect wiring, and examine capacitors/contactors to reduce breakdown risk.
-
Ensure Proper Airflow Pathways – Keep vents, louvers, and surrounding unit area clear of debris; unobstructed airflow improves comfort and efficiency.
-
Monitor Refrigerant Lines & R32 Charge – Have a professional verify R32 refrigerant levels and insulation to maintain cooling capacity and prevent compressor stress.
-
Schedule Annual Professional HVAC Service – Annual tune‑ups help detect combustion, heat exchanger, and burner issues early, optimizing heating and cooling year‑round.
