The Goodman Heat Pump Split System is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, the Goodman Heat Pump Split System is a perfect choice for all of your heating and cooling needs.
Features
- Designed to cover a smaller house in average climates
- 4 Ton, 15.2 SEER2 heat pump condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed bi-flow filter drier
-
Air Handler
- 4 ton air handler
- Electric heat compatible
- Optimized for use with R-32 refrigerant
- Multi-speed, direct drive ECM blower motor
- Multi-positional (upflow, downflow, or horizontal)
Specifications
| 4 Ton 15.2 SEER2 High Efficiency Goodman Heat Pump - 7.8 HSPF2 | |
|---|---|
| SKU | GLZS5BA4810 |
| Weight | 292.000000 |
| Manufacturer | Goodman |
| Replaces | GSZ160481 |
| Cooling BTU | 48,000 |
| Heating BTU | 48,000 |
| Blower Motor | Single Speed Motor |
| Decibel Level (dBA) | 74 |
| Horsepower | 0.25 HP |
| Refrigerant | R32 |
| SEER2 | 15.2 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Electrical | 208/230v 1 Phase 60Hz |
| Max Breaker Size | 45 Amps |
| Min. Breaker Size | 26.2 Amps |
| Tonnage | 4 Ton |
| Connection | Sweat |
| Height | 36 1/2" |
| Width | 35 1/2" |
| Depth | 35 1/2" |
Manual
- GSZH5 Installation Manual
- GSZH5 Specifications Shee
- AMST Installation Manual
- AMST Specifications Sheet
What our Experts Think
-
Efficient Year‑Round Comfort with Modern R‑32 Refrigerant
The Goodman GLZS5BA4810 4 Ton Heat Pump uses R‑32 refrigerant, delivering 48,000 BTU cooling and heating capacity with a 15.2 SEER2 rating for balanced energy performance throughout the seasons. -
Reliable Single‑Stage Scroll Compressor
A single‑stage scroll compressor offers dependable, consistent performance with fewer moving parts—helping reduce service complexity and support long‑term reliability. -
SmartShift® Defrost System for Quiet Heating
Built‑in SmartShift® technology ensures smooth, quiet defrost cycles in heating mode, which enhances comfort without frequent noise disruptions. -
Durable Outdoor Construction
Heavy‑gauge galvanized‑steel cabinet with powder‑painted finish and steel louver coil guard protects against weather and corrosion, supporting longevity in outdoor installations. -
Installer Friendly Features
Factory‑installed accumulator, crankcase heater, high‑capacity muffler, and easy‑access service valves simplify installation and maintenance for HVAC professionals. -
Quiet Operation & Certified Performance
With around 73–74 dB noise level and AHRI/ETL certification, this unit is engineered for quieter operation while meeting industry performance standards.
Q&A
Q1: What type of HVAC system is this?
A: The Goodman GLZS5BA4810 is a 4 ton (48,000 BTU) heat pump split system designed for both heating and cooling in residential applications. It includes an outdoor heat pump condenser (must be paired with a compatible indoor air handler or coil).
Q2: What efficiency ratings does it have?
A: It delivers 15.2 SEER2 cooling efficiency and approximately 8.2 HSPF2 heating performance, providing balanced year‑round comfort and energy savings.
Q3: What refrigerant does this heat pump use?
A: The unit uses environmentally friendly R‑32 refrigerant, which helps improve efficiency and reduce environmental impact vs older refrigerants.
Q4: What kind of compressor and operation does it have?
A: It features a single‑stage scroll compressor for reliable, consistent performance throughout heating and cooling cycles.
Q5: What are the key durability features?
A: The heat pump has a heavy‑gauge galvanized steel cabinet, removable grille top, steel coil guard, extended‑life capacitor, factory‑installed accumulator and crankcase heater, and is AHRI certified and ETL listed for performance and safety.
Q6: How loud is the unit?
A: Typical sound levels are around the mid‑70 dB range during operation, offering reasonable outdoor noise control.
Q7: What installation flexibility does it offer?
A: When paired with a multi‑positional compatible indoor air handler, this system supports upflow, downflow, or horizontal installations for versatile home layouts.
Maintenance Tips
-
Replace Air Filters Every 1–3 Months – Clean filters protect the indoor coil and blower, maintaining proper airflow and system efficiency.
-
Clean Evaporator & Condenser Coils Annually – Dust and debris on all‑aluminum coils reduce heat transfer and SEER2 efficiency.
-
Inspect Refrigerant Lines & TXV – Ensure R32 refrigerant lines are leak-free and the thermostatic expansion valve regulates refrigerant correctly for efficient cooling/heating.
-
Maintain Proper Airflow – Keep supply and return vents clear and ensure blower fans operate without obstruction for optimal performance.
-
Check Condensate Drain & Pan – Prevent water buildup and microbial growth by keeping the condensate drain clear.
-
Inspect Electrical Components – Regularly check contactors, capacitors, and wiring for wear or corrosion to prevent failures.
-
Schedule Professional Annual Maintenance – Technicians should check refrigerant levels, clean coils, verify SEER2 performance, and ensure safe multi-positional heat pump operation.