Goodman - 3 Ton/80,000 BTU 80% AFUE Low NOx Gas Furnace and Air Conditioner System - Downflow - 14.5 SEER2 - R32 - GLXS4BA3610 / CAPTA4230C3 / GD9T800805CX
Goodman - 3 Ton/80,000 BTU 80% AFUE Low NOx Gas Furnace and Air Conditioner System - Downflow - 14.5 SEER2 - R32 - GLXS4BA3610 / CAPTA4230C3 / GD9T800805CX
Couldn't load pickup availability
Goodman - 3 Ton/80,000 BTU 80% AFUE Low NOx Gas Furnace and Air Conditioner System - Downflow - 14.5 SEER2 - R32 - GLXS4BA3610 / CAPTA4230C3 / GD9T800805CX
Goodman - 3 Ton/80,000 BTU 80% AFUE Low NOx Gas Furnace and Air Conditioner System - Downflow - 14.5 SEER2 - R32 - GLXS4BA3610 / CAPTA4230C3 / GD9T800805CX
A Goodman combination system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman furnace and air conditioning system is the perfect choice for all of your heating and cooling needs.
Features
- All-Aluminum Coil: Goodman's evaporator coils maximize surface area and optimize heat transfer for efficient comfort by using a reliable all-aluminum design complete with sine fins and grooved tubes.
- Internal Thermostatic Expansion Valve: Goodman's CAPTA units have a factory-installed internal thermostatic expansion valve, which streamlines installation and maintains ideal refrigerant flow for your system.
- Cabinet Durability: Providing superior longevity and efficiency, CAPTA units have a galvanized, embossed, and insulated cabinet that protects the coil and prevents air leakage.
- Condensate Management: Keeping your system sage and operational, the CAPTA units feature a foil-faced insulation to inhibit the formation of condensate and a rust-resistant, DecaBDE-free thermoplastic drain pan secondary drain connections. The drain pan is UV-resistant.
- R32 Compatibility: Complies with Clean Air Act New Refrigerant Requirements.
- 10-Year Limited Warranty
Specifications
| SKU | GLXS4BA3610 |
|---|---|
| Weight | 173.000000 |
| Manufacturer | Goodman |
| Replaces | GSXN403610 |
| Product Features | New Refrigerant Compliant |
| Cooling BTU | 36,000 |
| Decibel Level (dBA) | 67 |
| Horsepower | 1/6 HP |
| Refrigerant | R32 |
| SEER2 | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Electrical | 208/230v 1 Phase 60Hz |
| Max Breaker Size | 30 Amps |
| Min. Breaker Size | 17.8 Amps |
| Tonnage | 3 Ton |
| Connection | Sweat |
| Height | 39 1/2" |
| Width | 29" |
| Depth | 29" |
Owner's Manual
- GLXS4B Specifications
- GLXS4B Installation Manual
- Warranty Information
- CHPTA Installation Manual
- CHPTA Specifications Sheet
What our Experts Think
-
Balanced Heating & Cooling Performance
• Paired 3 ton air conditioner with 80,000 BTU 80% AFUE two‑stage gas furnace delivers year‑round comfort for medium homes.
• Two‑stage heat improves comfort by moderating temperature swings and reducing cycling noise. -
Modern Efficiency and Refrigerant
• 14.5 SEER2 cooling efficiency helps reduce seasonal energy costs vs older systems.
• Uses R‑32 refrigerant, which offers better energy performance and a lower global warming potential than older refrigerants. -
Quality Airflow & Comfort Control
• 9‑speed ECM blower enables flexible airflow settings for optimized distribution and quieter operation.
• Matched TXV‑metered evaporator coil supports stable cooling performance across conditions. -
Installation Flexibility
• Furnace supports downflow or horizontal orientations, making it easier to adapt to different attic or basement duct layouts.
• Standard 24 V thermostat compatibility simplifies control upgrades. -
Value & Reliability
• Robust steel cabinets, service‑friendly access points, and protective components like filter driers and high‑pressure switches support lasting performance.
• Standard warranty coverage (e.g., 10 years parts when registered) adds peace of mind.
Q&A
Q: What size area is this HVAC system designed for?
A: The 3 ton system is typically suited for medium homes (~1,500–1,800 sq ft), but exact sizing depends on insulation, climate, and ductwork.
Q: What components are included in this system?
A: It includes a 3 ton R‑32 outdoor AC condenser (GLXS4BA3610), a cased evaporator coil (CAPTA4230C3), and an 80,000 BTU gas furnace (GD9T800805CX)—all matched for optimal performance.
Q: What are the efficiency ratings?
A: 14.5 SEER2 cooling efficiency and 80% AFUE heating efficiency deliver reliable comfort with balanced energy use.
Q: What does “Low NOx” mean?
A: “Low NOx” indicates reduced nitrogen oxide emissions from the furnace, helping meet stricter environmental standards in many regions.
Q: Is this system good for year‑round climate control?
A: Yes. It provides cooling in summer and gas heating in winter, making it a versatile central HVAC solution for climates needing both functions.
Q: What fuel and refrigerant does it use?
A: The furnace uses natural gas (convertible to propane), and the AC uses environmentally friendly R‑32 refrigerant.
Q: What installation orientations are supported?
A: The furnace supports downflow (and often horizontal) installation, offering flexibility in basements, attics, and closets.
Q: Is the blower efficient and quiet?
A: Yes. A multi‑speed ECM blower motor helps regulate airflow efficiently and quietly across seasons.
Maintenance Tips
-
Replace Air Filters Regularly
Check monthly; replace every 1–3 months to maintain airflow, efficiency, and prevent dust buildup in both furnace and AC. -
Clean Condenser and Evaporator Coils
Dirt on coils reduces cooling efficiency. Schedule annual professional cleaning. -
Inspect the Furnace Burner and Heat Exchanger
Annual inspection ensures safe operation, proper combustion, and optimal 80% AFUE performance. -
Check the Condensate Drain and Pan
Clear the drain line to prevent water damage and maintain AC efficiency. -
Maintain Outdoor Unit Clearance
Keep 2–3 ft around the condenser free of debris for proper airflow. -
Verify Thermostat and System Operation
Confirm heating and cooling cycles function correctly and thermostat is calibrated. -
Schedule Annual Professional Service
A certified technician should check refrigerant levels, electrical connections, gas lines, and blower operation for peak performance and safety.
