Goodman - 3 Ton/60,000 BTU 92% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - CHPTA3630B3
Goodman - 3 Ton/60,000 BTU 92% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - CHPTA3630B3
Couldn't load pickup availability
Goodman - 3 Ton/60,000 BTU 92% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - CHPTA3630B3
Goodman - 3 Ton/60,000 BTU 92% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - CHPTA3630B3
A Goodman combination system is an excellent way to keep your home cozy in winter and cool in summer. With top-notch features and a budget-friendly price, it's a smart choice for any homeowner.
Features
- This furnace is ideal to heat a smaller house (depending on climate)
- 60,000 BTU 92% efficient natural gas furnace
- Requires plastic/PVC flue venting
- Complies with Clean Air Act New Refrigerant Requirements
- Can be used in the upflow or horizontal orientation
- Can be converted to an LP furnace with a conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
- Ideal size to cover a small house in ideal climates
- 3 ton, 14.3 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Fully charged for up to 15' of line set
- Low sound output
- Factory-installed filter drier
- 3 ton horizontal evaporator coil
- Can be used with heat pump and AC-only condensers
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
- Factory-installed TXV kit
Specifications
| SKU | GLXS4BA3610 |
|---|---|
| Weight | 173.000000 |
| Manufacturer | Goodman |
| Replaces | GSXN403610 |
| Product Features | New Refrigerant Compliant |
| Cooling BTU | 36,000 |
| Decibel Level (dBA) | 67 |
| Horsepower | 1/6 HP |
| Refrigerant | R32 |
| SEER2 | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Electrical | 208/230v 1 Phase 60Hz |
| Max Breaker Size | 30 Amps |
| Min. Breaker Size | 17.8 Amps |
| Tonnage | 3 Ton |
| Connection | Sweat |
| Height | 39 1/2" |
| Width | 29" |
| Depth | 29" |
Manual
- GLXS4B Specifications
- GLXS4B Installation Manual
- CHPTA Installation Manual
- CHPTA Specifications Sheet
-
GR9S92 Specifications Sheet
What our Experts Think
-
High Efficiency: 92% AFUE furnace paired with 15.2 SEER2 AC provides reliable year-round comfort.
-
Optimal Capacity: 3 Ton / 60,000 BTU output ideal for medium to large homes.
-
Horizontal Installation: Designed for seamless integration into horizontal ductwork layouts.
-
Reliable Performance: Engineered for consistent, dependable heating and cooling.
-
Eco-Friendly Refrigerant: AC uses R32 to reduce environmental impact.
-
Durable Build: Built for long-term reliability across diverse climates.
-
Quiet Operation: Optimized for minimal noise in both heating and cooling modes.
Q&A
Q: What’s included in this HVAC system?
A: This matched split system bundles a Goodman 3 ton R32 central air conditioner condenser (GLXS4MA3610), a horizontal cased evaporator coil with factory‑installed TXV (CHPTA3630B3), and a 60,000 BTU 92% AFUE gas furnace (GR9S920603BN) for complete year‑round comfort.
Q: What cooling capacity and efficiency does it deliver?
A: The outdoor unit provides 3 tons (36,000 BTU) of cooling with a 15.2 SEER2 efficiency rating, helping reduce energy costs while keeping your home comfortably cool.
Q: How efficient and powerful is the heating component?
A: The gas furnace delivers 60,000 BTU input with 92% AFUE, meaning most fuel is converted into heat — ideal for small to medium homes or zones.
Q: What refrigerant does the system use?
A: Uses R‑32 refrigerant, a more environmentally responsible option with lower global warming potential than many older refrigerants.
Q: What installation orientation does it support?
A: Designed for horizontal installation (often attic or closet applications) with flexibility for installation orientation in restricted spaces.
Q: What are the key features of the evaporator coil?
A: The CHPTA3630B3 coil has an all‑aluminum design, factory‑installed TXV for precise refrigerant control, foil‑faced insulation and rust‑resistant drain pan for durability and efficient operation.
Q: What blower and control features does the furnace include?
A: The furnace features a multi‑speed ECM blower for smoother airflow and quieter operation, plus safety and diagnostic controls for dependable performance.
Maintenance Tips
-
Replace air filters every 1–3 months to maintain airflow and system efficiency.
-
Keep supply and return vents clear of furniture, dust, and debris.
-
Maintain 2–3 feet of clearance around the furnace and condenser for safe operation.
-
Inspect the condensate drain line regularly to prevent clogs and water buildup.
-
Check thermostat settings and operation for proper heating and cooling cycles.
-
Examine vent pipes, ductwork, and connections for leaks or blockages.
-
Clean blower compartment and indoor coil surfaces to reduce dust buildup.
-
Inspect the outdoor air conditioner coil periodically and remove debris to maintain efficiency.
-
Listen for unusual noises such as rattling, buzzing, or humming indicating potential mechanical issues.
-
Schedule annual professional HVAC maintenance to inspect burners, heat exchanger, refrigerant levels, and electrical components.