Goodman - 3.5 Ton/42,000 BTU Air Conditioner Condenser - SEER2 13.4 - Single Stage - R32 - GLXS3BN4210
Goodman - 3.5 Ton/42,000 BTU Air Conditioner Condenser - SEER2 13.4 - Single Stage - R32 - GLXS3BN4210
Couldn't load pickup availability
Goodman - 3.5 Ton/42,000 BTU Air Conditioner Condenser - SEER2 13.4 - Single Stage - R32 - GLXS3BN4210
Goodman - 3.5 Ton/42,000 BTU Air Conditioner Condenser - SEER2 13.4 - Single Stage - R32 - GLXS3BN4210
The Goodman GLXS3BN4210 is a cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GLXS3BN4210 is an inexpensive condenser to cool your home when paired with an AC coil.
Features
- Ideal size to cover a medium-sized house
- 3.5 ton, 13.4 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed filter drier
Specifications
| 3.5 Ton 13.4 SEER2 Goodman Air Conditioner Condenser - R32 | |
|---|---|
| SKU | GLXS3BN4210 |
| Weight (in lbs) | 195.000000 |
| Brand/Manufacturer | Goodman |
| Replaces | GSX130421 and GSXN3N4210 |
| Cooling BTU | 42,000 |
| Blower Motor | Single Speed PSC Motor |
| Decibel Level (dBA) | 73 |
| Horsepower | 1/4 HP |
| Refrigerant | R32 |
| SEER2 (Efficiency) | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size | 30 Amps |
| Min. Breaker Size | 19.4 Amps |
| Tonnage | 3.5 Ton |
| Connection | Sweat |
| Height | 35 3/4" |
| Width | 26" |
| Depth | 26" |
Manual
What our Experts Think
-
Strong Cooling for Mid‑Size Homes
The Goodman GLXS3BN4210 3.5 Ton AC Condenser delivers 42,000 BTU of cooling capacity—ideal for medium‑sized homes and spaces needing reliable seasonal performance. -
R‑32 Refrigerant for Better Efficiency & Climate Impact
Engineered to use R‑32 refrigerant, this unit meets modern environmental standards with lower global warming potential compared to older refrigerants, improving both efficiency and sustainability. -
Standard‑Level SEER2 Performance
A 13.4 SEER2 rating positions this condenser as a value‑oriented, everyday cooling solution, balancing upfront cost with seasonal efficiency popular in standard residential installs. -
Single‑Stage Scroll Compressor
The single‑stage scroll compressor provides steady, consistent cooling with fewer moving parts—translating to reliable operation and simplified servicing over time. -
Quiet & Durable Outdoor Design
With 73 dB noise level and a powder‑painted, galvanized steel cabinet with protective louver guard, this condenser is built to withstand outdoor conditions with minimized operational noise. -
Installer‑Friendly Features
Factory‑installed filter drier, easily accessible service valves, and single‑panel control access help trained HVAC pros install, maintain, and troubleshoot the unit more efficiently.
Q&A
Q1: What type of HVAC component is this?
A: The Goodman GLXS3BN4210 is an outdoor air conditioner condenser designed for split‑system cooling (no heating included) and must be paired with a compatible indoor coil or air handler.
Q2: What size and cooling capacity does it offer?
A: It delivers approximately 3.5 tons of cooling capacity (~42,000 BTU/h), suitable for medium‑sized residential homes.
Q3: What is the efficiency rating?
A: This condenser is rated at 13.4 SEER2, providing seasonal energy efficiency that meets DOE standards in applicable regions.
Q4: Which refrigerant does it use?
A: It uses R‑32 refrigerant, a more energy‑efficient and lower environmental impact choice than older refrigerants.
Q5: What type of compressor and operation does it have?
A: The unit features a single‑stage scroll compressor for consistent and dependable cooling performance.
Q6: What are the durability and construction features?
A: The condenser has a heavy‑gauge galvanized steel cabinet, powder‑coat finish with UV resistance, wire coil guard, and factory‑installed filter drier for long‑lasting outdoor durability.
Q8: What warranty support is offered?
A: The unit includes a 10‑year limited parts warranty when registered online.
Q9: Where is this condenser best applied?
A: Ideal for residential cooling applications, pairing with an indoor coil or air handler to complete a split‑system HVAC installation.
Maintenance Tips
-
Keep the Outdoor Coil Clean – Remove leaves, dirt, and debris regularly to maintain heat transfer efficiency and reduce compressor strain. (hvacdirect.com)
-
Check Refrigerant Lines & Connections – Inspect for leaks and proper insulation on R32 refrigerant lines; low refrigerant reduces cooling performance.
-
Ensure Proper Airflow Around Condenser – Maintain at least 2 feet of clearance on all sides to allow unobstructed airflow and optimal condenser operation.
-
Inspect Electrical Components – Periodically check contactors, capacitors, and wiring for wear or corrosion to prevent unexpected failures.
-
Level the Condenser Pad – A stable, level pad prevents stress on the compressor and refrigerant lines.
-
Schedule Annual Professional Maintenance – HVAC technicians should clean coils, test pressures, check SEER2 performance, and ensure safe single-stage operation.
-
Protect During Off-Season – Consider a breathable cover in winter to prevent debris accumulation while avoiding moisture trapping.