A Goodman Gas Furnace and Air Conditioner System is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman Gas Furnace and Air Conditioner System is the perfect choice for all of your heating and cooling needs.
Features
- Ideal size to cover a medium-sized house
- 2 ton, 13.4 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed filter drier
- 2.5 ton horizontal evaporator coil
- Can be used with heat pump and AC-only condensers
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
- Factory-installed TXV kit
- This furnace is ideal to heat a medium-sized house (depending on climate)
- 80,000 BTU 96% AFUE natural gas furnace
- Requires plastic/PVC flue venting
- Can be used in the upflow or horizontal orientation
- Can be converted to an LP furnace with an optional conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
Specifications
| 2 Ton 13.4 SEER2 Goodman Air Conditioner Condenser - R32 | |
|---|---|
| SKU | GLXS3BN2410 |
| Weight | 130.000000 |
| Manufacturer | Goodman |
| Replaces | GSX130241 and GSXN3N2410 |
| Product Features | New Refrigerant Compliant |
| Cooling BTU | 24,000 |
| Decibel Level (dBA) | 74 |
| Horsepower | 1/8 HP |
| Refrigerant | R32 |
| SEER2 | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size | 15 Amps |
| Min. Breaker Size | 10.9 Amps |
| Tonnage | 2 Ton |
| Connection | Sweat |
| Height | 27.5" |
| Width | 26" |
| Depth | 26" |
Manual
- GLXS3B Specifications
-
GLXS3B Installation Manual
- CHPTA Installation Manual
- CHPTA Specifications Shee
- GM9C96 Installation Manual
- GM9C96 Specifications Sheet
What our Experts Think
-
Top‑Tier Efficiency: The Goodman GRVT960403BN Gas Furnace offers 96% AFUE, meaning nearly all fuel is converted into heat — ideal for lower utility bills and cold‑climate performance.
-
Variable‑Speed Blower Advantage: The variable‑speed motor delivers consistent airflow, quieter operation, and better humidity control than standard blowers.
-
Two‑Stage Heating Comfort: Two‑stage operation lets the furnace run at a lower output most of the time, resulting in more even temperatures and fewer temperature swings.
-
Right‑Sized 40,000 BTU Capacity: Perfect for smaller homes, apartments, or condos, providing efficient, responsive heat without excess energy use.
-
Flexible Installation Fit: The 17.5" compact cabinet supports upflow and horizontal configurations, making it easier to install in tight spaces like closets, attics, or basements.
-
Durable, Dependable Build: Engineered with quality components and a robust heat exchanger for long‑term reliability and peace of mind.
-
Comfort + Value Combination: Excellent balance of high efficiency, advanced airflow control, and versatile installation, making this furnace a smart choice for efficient home heating.
Q&A
Q: What cooling capacity does this condenser provide?
A: This Goodman condenser delivers 4 tons (48,000 BTU) of cooling, making it suitable for medium to large homes or commercial spaces when paired with the correct indoor components.
Q: What does SEER2 15.2 mean?
A: SEER2 15.2 indicates improved seasonal energy efficiency under updated testing standards, helping lower cooling costs compared to lower SEER units.
Q: What type of operation and compressor does it use?
A: It uses a single‑stage scroll compressor, offering simple, reliable cooling performance.
Q: What refrigerant is used?
A: This unit uses R32 refrigerant, which is environmentally friendlier and more efficient than many older refrigerants.
Q: What are the installation and electrical requirements?
A: Designed for 208/230 V single‑phase power, pre‑charged for up to 15 ft of line set (indoor coil/air handler sold separately).
Q: What are the physical dimensions?
A: Approximate dimensions are 35.5″ W × 35.5″ D × 36.5″ H.
Q: How loud is the unit during operation?
A: Typical operating sound is around 73‑76 dBA, which is normal for residential outdoor AC condensers.
Maintenance Tips
-
Clean the Condenser Coil: Remove leaves, dirt, and debris regularly to maintain efficient heat transfer and optimal cooling.
-
Maintain Clearance Around Unit: Keep at least 2–3 ft of space around the condenser for proper airflow and prevent overheating.
-
Inspect Refrigerant Lines: Check 3/8" liquid and 7/8" suction lines for insulation damage or leaks.
-
Rinse Fins Carefully: Use a garden hose to gently clean fins, avoiding bending or damaging them.
-
Check Electrical Connections: Inspect wiring, disconnect box, and capacitor for secure and corrosion-free operation.
-
Monitor Noise & Performance: Normal operation is quiet; unusual sounds or weak cooling may indicate service is needed.
-
Schedule Annual Professional Service: A licensed technician should check compressor, fan motor, refrigerant charge, and system pressure yearly to maintain 15.2 SEER2 efficiency.