Goodman - 2 Ton/80,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.3 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/80,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.3 SEER2 - R32 - CHPTA2426B3
Couldn't load pickup availability
Goodman - 2 Ton/80,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.3 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/80,000 BTU 96% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14.3 SEER2 - R32 - CHPTA2426B3
A Goodman combination system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman furnace and air conditioning system is the perfect choice for all of your heating and cooling needs.
Features
- This furnace is ideal to heat a smaller house (depending on climate)
- 80,000 BTU 96% efficient natural gas furnace
- Requires plastic/PVC flue venting
- Complies with Clean Air Act New Refrigerant Requirements
- Can be used in the upflow or horizontal orientation
- Can be converted to an LP furnace with a conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
- Ideal size to cover a small house in ideal climates
- 2 ton, 14.3 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Fully charged for up to 15' of line set
- Low sound output
- Factory-installed filter drier
- 2 ton horizontal evaporator coil
- Can be used with heat pump and AC-only condensers
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
- Factory-installed TXV kit
Specifications
| 80,000 BTU 96% AFUE 9-Speed Single Stage Goodman Gas Furnace - Upflow/Horizontal | |
|---|---|
| SKU | GR9S960803BN |
| Weight | 118.000000 |
| AHRI Certificate Number | 215224973 |
| Config Search | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| Manufacturer | Goodman |
| Product Features | New Refrigerant Compliant |
| Furnace Efficiency / AFUE | 96% |
| Heating BTU | 80,000 |
| Blower Motor | 9 Speed - ECM |
| Maximum CFM | 1200 |
| Horsepower | 1/2 HP |
| Configuration | Upflow/Horizontal |
| Energy Star | Yes |
| Electrical | 115 V. 1 Phase 60 Hz |
| Max Breaker Size | 15 Amps |
| Min. Breaker Size | 10.1 Amps |
| Burner Stages | Single |
| Fuel Type | Propane, Natural Gas |
| Height | 34.5" |
| Width | 17.5" |
| Depth | 28.75" |
Manual
- GLXS4B Specifications
- GLXS4B Installation Manual
- CHPTA Installation Manual
- CHPTA Specifications Sheet
- GR9S96 Specifications Sheet
What our Experts Think
-
Complete Comfort System – Combines a **2 ton air conditioner with an 80,000 BTU, 96% AFUE gas furnace to deliver efficient year‑round cooling and heating for small to medium homes.
-
High Heating Efficiency (96% AFUE) – Maximizes fuel‑to‑heat conversion to lower winter heating costs compared with standard‑efficiency units.
-
14.3 SEER2 Cooling Performance – Meets modern efficiency guidelines, helping reduce cooling energy use and provide comfortable indoor temperatures.
-
Horizontal Configuration – Designed for attic or crawl‑space installations, offering flexible placement in common residential layouts.
-
R‑32 Refrigerant Compatibility – Built for next‑generation, environmentally improved refrigerant, aligning with modern HVAC standards.
-
Multi‑Speed ECM Blower Motor – Provides quieter airflow, improved comfort, and better temperature distribution compared to basic blower motors.
-
Factory‑Matched Components – Engineered to work together for optimized system performance, reliability, and longevity when installed professionally.
-
Durable Construction & Support – Built with quality materials and backed by Goodman’s parts network for dependable long‑term use.
Q&A
Q: What components are included in this system?
A: This matched HVAC package includes a Goodman 2 ton 14.3 SEER2 R32 air conditioner condenser, a horizontal evaporator coil (CHPTA2426B3) with factory‑installed TXV, and a 96% AFUE 80,000 BTU gas furnace — all designed to work together for year‑round comfort.
Q: What heating and cooling capacity does it offer?
A: The 2 ton air conditioner cools spaces up to roughly 1,000–1,800 sq ft (varies with home size and climate), while the 80,000 BTU furnace delivers high‑efficiency heating for medium‑sized areas.
Q: What does 14.3 SEER2 mean?
A: 14.3 SEER2 is the seasonal energy efficiency rating for the AC, which helps lower cooling energy use and electricity costs compared to older, lower‑SEER systems.
Q: What does 96% AFUE mean for the furnace?
A: 96% AFUE means 96% of fuel is converted into heat, delivering high heating efficiency and reduced natural gas costs versus less efficient units.
Q: What are the benefits of the horizontal CHPTA2426B3 coil?
A: The CHPTA2426B3 coil is optimized for R32 refrigerant, with an all‑aluminum design and factory‑installed TXV for precise refrigerant control and efficient performance.
Q: How does the furnace perform?
A: The 96% AFUE gas furnace features a multi‑speed ECM blower, aluminized steel heat exchanger, and reliable two‑stage operation to balance performance and comfort.
Q: What refrigerant does the system use?
A: This system uses R32 refrigerant, which improves energy efficiency and has a lower environmental impact than many older refrigerants.
Maintenance Tips
-
Replace Air Filters Every 1–3 Months: Keeps airflow optimal, protects both furnace and AC components, and maintains efficiency.
-
Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for consistent heating and cooling.
-
Clean Outdoor AC Condenser: Rinse coils every 3–6 months to preserve SEER2 performance and prevent debris buildup.
-
Annual Professional Inspection: Have a certified technician check burners, heat exchanger, gas pressure, and airflow for safe furnace operation.
-
Inspect Refrigerant Lines & Insulation: Ensure lines are intact and insulation is in good condition for optimal R32 efficiency.
-
Maintain Condensate Drains: Keep furnace and AC drain lines clear to prevent water buildup or system shutdowns.
-
Schedule Yearly Professional Service: Inspect electrical connections, airflow, and overall system performance.
-
Monitor for Unusual Signs: Strange noises, odors, or inconsistent heating/cooling require prompt professional attention.