Goodman - 2 Ton/60,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM32406031
Goodman - 2 Ton/60,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM32406031
Couldn't load pickup availability
Goodman - 2 Ton/60,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM32406031
Goodman - 2 Ton/60,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM32406031
The Goodman GPGM32406031 is a gas heat and electric AC packaged unit, ready for any application where it is not convenient to have an indoor furnace or air handler. At 13.4 SEER2 and 80% AFUE, the GPGM32406031 is an inexpensive option with a standard efficiency designed for rooftop and next-to-building applications.
Features
- 2 ton, 60,000 BTU packaged unit
- 13.4 SEER2, 80% AFUE
- Downflow or horizontal discharge installation options
- Fully charged and ready to install
- Low sound output
- Low NOx compliant
Specifications
| 2 Ton 13.4 SEER2 60,000 BTU Goodman Gas Packaged Unit - R32 | |
|---|---|
| SKU | GPGM32406031 |
| Weight (in lbs) | 417.000000 |
| AHRI Certificate Number | 209319520 |
| Brand/Manufacturer | Goodman |
| Replaces | GPU1424040M41, GPG1424060M41, 663051662339 |
| Furnace Efficiency / AFUE | 80% |
| Cooling BTU | 23,000 BTU |
| Heating BTU | 60,000 BTU |
| Blower Motor | Multi-Speed |
| Maximum CFM | 800 |
| Decibel Level (dBA) | 78 decibels |
| Configuration | Downflow/Horizontal |
| Refrigerant | R32 |
| SEER2 (Efficiency) | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size | 20 amps |
| Tonnage | 2 Ton |
| Fuel Type | Natural Gas |
| Height | 34 1/2" |
| Width | 47" |
| Depth | 51" |
Manual
- GPGM3 Specifications Sheet
- GPGM3 Installation Manual
- GPGM3 Replacement Parts Manual
-
GPGM3 Service Manual
What our Experts Think
-
All‑in‑One Heating & Cooling Simplicity
The Goodman GPGM32406031 is a 2 Ton, 60,000 BTU gas‑electric packaged HVAC unit that combines heating, cooling, and airflow in a single self‑contained outdoor cabinet — ideal where indoor air handlers or furnaces aren’t practical. -
Standard Efficiency That Meets Codes
With 13.4 SEER2 cooling and ~80–81 % AFUE heating, this unit hits nationwide efficiency standards for both seasons, offering balanced energy performance without complexity. -
Built for Modern R‑32 Refrigerant
Factory‑charged with R‑32 refrigerant, it supports lower global warming potential and improved efficiency compared with older refrigerants — aligning with current HVAC best practices. -
Versatile Installation Options
Multi‑position design works in downflow or horizontal layouts (roof or ground), giving installers the flexibility to adapt the unit to varied placement needs. -
Quiet, Durable Outdoor Build
Heavy‑gauge steel cabinet with insulation helps control sound (around 78 dB), while corrosion‑resistant construction supports all‑weather outdoor operation. -
Efficient Airflow & Reliable Components
Features like a multi‑speed ECM blower motor, scroll compressor, and direct spark ignition with diagnostics contribute to consistent comfort and easier servicing.
Q&A
Q1: What type of HVAC system is this?
A: The Goodman GPGM32406031 is a self‑contained gas/electric packaged HVAC unit that combines both cooling and heating in one outdoor cabinet — no indoor furnace or coil required.
Q2: What are the cooling and heating capacities?
A: It provides 2 tons of cooling (~22,800 BTU) with 13.4 SEER2 efficiency and 60,000 BTU of natural gas heating with approximately 80–81% AFUE.
Q3: What refrigerant does the unit use?
A: This packaged unit is factory‑charged with R‑32 refrigerant, offering lower environmental impact and improved energy performance compared with older refrigerants.
Q4: How is airflow configured?
A: It supports downflow or horizontal discharge airflow, making it suitable for rooftop or ground‑level installations with flexible orientation.
Q5: What type of blower and compressor does it include?
A: The unit features a multi‑speed ECM blower motor and a single‑stage rotary scroll compressor for reliable, year‑round comfort and quieter performance.
Q6: What are the electrical requirements?
A: The system operates on 208/230 V, single‑phase, 60 Hz power and typically requires a 20–25 A circuit breaker depending on local code and setup.
Q7: What durability and noise features does it offer?
A: Built with a heavy‑gauge steel cabinet, factory‑installed insulation, and coil guard, it’s designed for rugged outdoor conditions and low operational noise (~78 dB).
Maintenance Tips
-
Replace Air Filters Frequently – Change or clean filters every 1–3 months to maintain proper airflow and protect internal components from dust buildup.
-
Clean Condenser & Evaporator Coils Annually – Dirt on coils reduces heat transfer and efficiency; gentle rinsing of the outdoor coil and professional indoor coil cleaning preserves SEER2 performance.
-
Keep Surrounding Area Clear – Remove leaves, grass, and debris around the unit to ensure unobstructed airflow and reduce strain on the blower and compressor.
-
Inspect Electrical Connections & Controls – Periodically check wiring, terminals, capacitors, and contactors for wear or corrosion to avoid failures and improve reliability.
-
Check Condensate Drain Line & Pan – Ensure the drain line stays clear to prevent water backup and microbial growth, especially during cooling operation.
