A Goodman Gas Furnace and Air Conditioner System is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman Gas Furnace and Air Conditioner System is the perfect choice for all of your heating and cooling needs.
Features
- Ideal size to cover a medium-sized house
- 2 ton, 13.4 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed filter drier
- 2 ton horizontal evaporator coil
- Can be used with heat pump and AC-only condensers
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
- Factory-installed TXV kit
- This furnace is ideal to heat a medium house (depending on climate)
- 60,000 BTU 96% efficient natural gas furnace
- Requires plastic/pvc flue venting
- Can be used in the downflow or horizontal orientation
- Can be converted to an LP furnace with a conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
Specifications
| 2 Ton 13.4 SEER2 Goodman Air Conditioner Condenser - R32 | |
|---|---|
| SKU | GLXS3BN2410 |
| Weight | 130.000000 |
| Manufacturer | Goodman |
| Replaces | GSX130241 and GSXN3N2410 |
| Product Features | New Refrigerant Compliant |
| Cooling BTU | 24,000 |
| Decibel Level (dBA) | 74 |
| Horsepower | 1/8 HP |
| Refrigerant | R32 |
| SEER2 | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size | 15 Amps |
| Min. Breaker Size | 10.9 Amps |
| Tonnage | 2 Ton |
| Connection | Sweat |
| Height | 27.5" |
| Width | 26" |
| Depth | 26" |
Manual
- GLXS3B Specifications
-
GLXS3B Installation Manual
- CHPTA Installation Manual
- CHPTA Specifications Sheet
- GC9S96 Installation Manual
- GC9S96 Specifications Sheet
What our Experts Think
-
All‑Season Comfort Package – A complete system pairing a 2 ton air conditioner with a 60,000 BTU, 96% AFUE gas furnace for reliable year‑round heating and cooling in small to mid‑size homes.
-
96% AFUE High Heating Efficiency – High furnace efficiency means more of the fuel becomes heat, helping reduce winter heating costs compared with standard units.
-
13.8 SEER2 Cooling Performance – Delivers efficient cooling that meets modern energy standards, helping lower summer electricity use while improving indoor comfort.
-
Horizontal Installation Ready – Designed for horizontal duct layouts (attic or crawl space), offering flexibility for common residential installations.
-
R‑32 Refrigerant Compliance – Uses modern, lower‑impact R‑32 refrigerant, aligning with current environmental and efficiency standards.
-
Factory‑Matched Coil & TXV – The included horizontal evaporator coil with built‑in TXV improves refrigerant control and overall system efficiency when properly paired.
-
Durable Construction & Warranty Support – Quality cased coil design and Goodman’s 10‑year parts warranty (with registration) help ensure long‑term reliability.
-
Balanced Performance & Value – A well‑rounded system for homeowners who want solid performance and comfort without the premium cost of ultra‑high SEER or modulating systems.
Q&A
Q: What’s included in this Goodman HVAC system?
A: This matched comfort system includes a Goodman 2 ton 13.8 SEER2 R32 air conditioner condenser, a horizontal CHPTA2426B3 evaporator coil with factory‑installed TXV, and a 96% AFUE 60,000 BTU gas furnace engineered to work together for efficient heating and cooling.
Q: What size home is this system suited for?
A: With 2 ton (≈24,000 BTU) cooling and 60,000 BTU heating, it’s ideal for small to medium homes (~1,000–1,800 sq ft), depending on insulation, local climate, and duct design.
Q: What does 13.8 SEER2 mean?
A: 13.8 SEER2 is the seasonal energy efficiency rating for cooling. It means efficient cooling performance that can help lower electricity use compared with older or lower‑rated systems.
Q: What does 96% AFUE mean?
A: 96% AFUE indicates 96% of the fuel’s energy is converted to usable heat, delivering high‑efficiency heating and reduced natural gas costs.
Q: Why is the CHPTA2426B3 coil important?
A: The evaporator coil with a factory‑installed TXV precisely regulates refrigerant flow, enhancing cooling efficiency, comfort, and system responsiveness.
Q: What refrigerant does the system use?
A: The system uses R32 refrigerant, which provides higher energy efficiency and a lower environmental impact than many older refrigerants.
Q: What installation configuration does it support?
A: This system is designed for horizontal installation, perfect for attics, closets, or other tight mechanical spaces requiring sideways airflow.
Maintenance Tips
-
Replace Air Filters Every 1–3 Months: Maintains airflow, protects both furnace and AC components, and ensures efficiency.
-
Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for consistent heating and cooling.
-
Clean Outdoor AC Condenser: Rinse coils every 3–6 months to preserve SEER2 efficiency and prevent debris buildup.
-
Annual Professional Inspection: Have a certified technician check burners, heat exchanger, gas pressure, and airflow for safe furnace operation.
-
Inspect Refrigerant Lines & Insulation: Ensure lines are intact and insulation is in good condition for optimal R32 performance.
-
Maintain Condensate Drains: Keep both furnace and AC drain lines clear to prevent water issues or system shutdowns.
-
Schedule Yearly Professional Service: Inspect electrical connections, airflow, and overall system performance.
-
Monitor for Unusual Signs: Strange noises, odors, or inconsistent heating/cooling require prompt professional attention.