Goodman - 2 Ton/60,000 BTU 92% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - CHPTA3026B3
Goodman - 2 Ton/60,000 BTU 92% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - CHPTA3026B3
Couldn't load pickup availability
Goodman - 2 Ton/60,000 BTU 92% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - CHPTA3026B3
Goodman - 2 Ton/60,000 BTU 92% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15.2 SEER2 - R32 - CHPTA3026B3
A Goodman combination system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman furnace and air conditioning system is the perfect choice for all of your heating and cooling needs.
Features
- This furnace is ideal to heat a smaller house (depending on climate)
- 60,000 BTU 92% efficient natural gas furnace
- Requires plastic/PVC flue venting
- Complies with Clean Air Act New Refrigerant Requirements
- Can be used in the upflow or horizontal orientation
- Can be converted to an LP furnace with a conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
- Ideal size to cover a small house in ideal climates
- 2 ton, 14.3 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Fully charged for up to 15' of line set
- Low sound output
- Factory-installed filter drier
- 2.5 ton horizontal evaporator coil
- Can be used with heat pump and AC-only condensers
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
- Factory-installed TXV kit
Specifications
| 2 Ton 14.3 SEER2 Goodman Air Conditioner Condenser | |
|---|---|
| SKU | GLXS4BA2410 |
| Weight | 153.000000 |
| Manufacturer | Goodman |
| Replaces | GSX140241 |
| Cooling BTU | 24,000 |
| Blower Motor | Single Speed PSC Motor |
| Decibel Level (dBA) | 72 |
| Horsepower | 0.125 HP |
| Refrigerant | R32 |
| SEER2 | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Electrical | 208/230v 1 Phase 60Hz |
| Max Breaker Size | 15 Amps |
| Min. Breaker Size | 11.2 Amps |
| Tonnage | 2 Ton |
| Connection | Sweat |
| Height | 32 1/2" |
| Width | 26" |
| Depth | 26" |
Manual
- GLXS4B Specifications
- GLXS4B Installation Manual
- CHPTA Installation Manual
- CHPTA Specifications Sheet
- GM9S92 Installation Manual
-
GM9S92 Specifications Sheet
What our Experts Think
-
All‑Season Comfort Package – A complete HVAC system pairing a 2 ton air conditioner with a 60,000 BTU, 92% AFUE gas furnace that delivers year‑round cooling and heating for small to medium homes.
-
15.2 SEER2 Cooling Efficiency – Meets updated energy standards for efficient cooling performance that helps keep electricity costs down compared to older AC systems.
-
92% AFUE High Heating Efficiency – High furnace efficiency means most fuel converts to usable heat, reducing winter heating costs versus lower‑efficiency models.
-
Single‑Stage Cooling & Heating – Simple, dependable single‑stage operation ensures consistent performance with straightforward maintenance and repair.
-
Multi‑Speed ECM Furnace Blower – Provides quieter airflow, improved comfort, and better distribution than basic blower motors.
-
R‑32 Refrigerant Compliant – Uses modern, lower‑impact R‑32 refrigerant for environmental performance and future refrigerant standards compliance.
-
Horizontal Installation Ready – Designed for attic or crawl‑space horizontal duct layouts, offering installation flexibility.
-
Factory‑Matched Components – Matched condenser, coil, and furnace improve system efficiency, reliability, and longevity when installed by a qualified HVAC professional.
Q&A
Q: What’s included in this Goodman HVAC package?
A: This is a complete matched system with a 2 ton 15.2 SEER2 R32 air conditioner condenser, a 60,000 BTU 92% AFUE gas furnace, and a horizontal evaporator coil (CHPTA3026B3) with factory‑installed TXV.
Q: What size home is this system ideal for?
A: With 2 ton (≈24,000 BTU) cooling and 60,000 BTU heating, it’s well‑suited to small to medium homes (~1,000–1,800 sq ft) depending on insulation, climate, and ductwork.
Q: What does 15.2 SEER2 mean?
A: A 15.2 SEER2 rating indicates seasonal cooling efficiency, helping to lower cooling energy use and utility costs versus older, lower‑SEER systems.
Q: What does 92% AFUE mean for the furnace?
A: 92% AFUE means 92% of the fuel’s energy is converted to usable heat, offering efficient and cost‑effective heating for daily comfort.
Q: What are the furnace features?
A: The gas furnace uses a single‑stage burner with a multi‑speed blower motor, provides consistent heat output, and can be vented via plastic/PVC as required for high‑efficiency units.
Q: What does the CHPTA3026B3 evaporator coil do?
A: The CHPTA3026B3 horizontal coil is optimized for R32 refrigerant, with a factory‑installed TXV to improve cooling efficiency and is galvanized and insulated for durability.
Q: What refrigerant does the system use?
A: This system uses R32 refrigerant, which is more efficient and environmentally friendly than many older refrigerants.
Maintenance Tips
-
Replace Air Filters Every 1–3 Months: Maintains airflow, efficiency, and protects both furnace and AC components.
-
Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for consistent heating and cooling.
-
Clean Outdoor AC Condenser: Rinse coils every 3–6 months to maintain SEER2 performance and prevent debris buildup.
-
Annual Professional Inspection: Have a certified technician check burners, heat exchanger, gas pressure, and airflow for safe furnace operation.
-
Inspect Refrigerant Lines & Insulation: Ensure lines are intact and insulation is in good condition for optimal R32 efficiency.
-
Maintain Condensate Drains: Keep both furnace and AC drain lines clear to prevent water issues or system shutdowns.
-
Schedule Yearly Professional Service: Inspect electrical connections, airflow, and overall system performance.
-
Monitor for Unusual Signs: Strange noises, odors, or inconsistent heating/cooling should prompt immediate professional attention.