Goodman - 2 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15 SEER2 - R32 - CHPTA2426B3
Couldn't load pickup availability
Goodman - 2 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15 SEER2 - R32 - CHPTA2426B3
Goodman - 2 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 15 SEER2 - R32 - CHPTA2426B3
A Goodman gas furnace and air conditioner system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman gas furnace and air conditioner system is the perfect choice for all of your heating and cooling needs.
Features
- Ideal size to cover a small house in ideal climates
- 2 ton, 14.3 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Fully charged for up to 15' of line set
- Low sound output
- Factory-installed filter drier
- 2 ton horizontal evaporator coil
- Can be used with heat pump and AC-only condensers
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
- Factory-installed TXV kit
- This furnace is ideal to heat a small to medium house (in average climate conditions)
- 60,000 BTU 80% AFUE two stage variable speed natural gas furnace
- Requires metal flue venting
- Can be used in the upflow or horizontal orientation
- Can be converted to propane with an LP conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
Specifications
| 2 Ton 14.3 SEER2 Goodman Air Conditioner Condenser - R32 | |
|---|---|
| SKU | GLXS4BA2410 |
| Weight | 132.000000 |
| Manufacturer | Goodman |
| Replaces | GSXN402410 |
| Product Features | New Refrigerant Compliant |
| Cooling BTU | 24,000 |
| Decibel Level (dBA) | 74 |
| Horsepower | 1/8 HP |
| Refrigerant | R32 |
| SEER2 | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208/230v 1 Phase 60Hz |
| Max Breaker Size | 15 Amps |
| Min. Breaker Size | 10.9 Amps |
| Tonnage | 2 Ton |
| Connection | Sweat |
| Height | 27" |
| Width | 26" |
| Depth | 26" |
Manual
- GLXS4B Specifications
- GLXS4B Installation Manual
- CHPTA Installation Manual
- CHPTA Specifications Sheet
- GMVC80 Installation Manual
- GMVC80 Brochure
What our Experts Think
-
All‑Season Comfort Package – A matched HVAC system pairing a 1.5 ton air conditioner with a 60,000 BTU, 80% AFUE gas furnace that delivers reliable cooling in summer and dependable heat in winter.
-
14.5 SEER2 Cooling Efficiency – Meets modern DOE efficiency standards for cost‑effective summer cooling and lower electricity usage than older systems.
-
80% AFUE Gas Furnace – Converts a high percentage of fuel into heat, offering steady home heating at a strong value point.
-
Horizontal Configuration – Engineered for attic or crawl‑space installations with horizontal ductwork, maximizing installation flexibility.
-
R‑32 Refrigerant Ready – Designed for next‑generation R‑32 refrigerant, aligning with current environmental and regulatory standards.
-
Factory‑Matched Evaporator Coil with TXV – Helps ensure precise refrigerant metering and smooth performance across seasons.
-
Durable Construction & Warranty Support – Quality coil and system components backed by Goodman’s limited warranty when registered, increasing long‑term reliability.
-
Balanced Performance & Value – A well‑rounded package that provides efficient cooling and reliable heating at a competitive price point, ideal for small to medium homes.
Q&A
Q: What components are included in this Goodman HVAC package?
A: A complete matched system with a **1.5 ton R32 air conditioner condenser (≈18,000 BTU cooling), a horizontal evaporator coil (CHPTA1822B3) with factory‑installed TXV, and a 96% AFUE 80,000 BTU gas furnace for efficient year‑round comfort.
Q: What size space is this system designed for?
A: This system is typically ideal for small to medium homes (≈700–1,000 sq ft) depending on insulation, layout, and local climate.
Q: What does 14.5 SEER2 mean?
A: 14.5 SEER2 is the cooling efficiency rating — it reflects efficient seasonal cooling performance that helps reduce electricity use and cost compared with older, lower‑SEER units.
Q: What does 96% AFUE mean?
A: 96% AFUE means 96% of the furnace fuel is converted into usable heat, delivering high‑efficiency heating with lower natural gas costs.
Q: What are the key features of the included evaporator coil (CHPTA1822B3)?
A: The horizontal coil is optimized for R32 refrigerant, has an all‑aluminum design, and a factory‑installed TXV, which improves cooling efficiency and system responsiveness.
Q: What refrigerant does the system use?
A: This system uses R32 refrigerant, a modern, more efficient refrigerant with lower environmental impact.
Q: What installation orientation does it support?
A: It’s designed for horizontal left‑or‑right installation, suitable for attics, closets, or compact mechanical spaces.
Maintenance Tips
-
Replace Air Filters Every 1–3 Months: Maintains airflow, protects furnace and AC components, and ensures efficient operation.
-
Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for consistent heating and cooling.
-
Clean Outdoor AC Condenser: Rinse coils every 3–6 months to maintain SEER2 performance and prevent debris buildup.
-
Annual Professional Inspection: Have a certified technician check burners, heat exchanger, gas pressure, and airflow for safe and efficient furnace operation.
-
Inspect Refrigerant Lines & Insulation: Ensure lines are intact and insulation is in good condition for optimal R32 efficiency.
-
Maintain Condensate Drains: Keep furnace and AC drain lines clear to prevent water issues or system shutdowns.
-
Schedule Yearly Professional Service: Inspect electrical connections, airflow, and overall system performance.
-
Monitor for Unusual Signs: Strange noises, odors, or inconsistent heating/cooling require prompt professional attention.