The Goodman GPGM32404031 is a gas heat and electric AC packaged unit, ready for any application where it is not convenient to have an indoor furnace or air handler. At 13.4 SEER2 and 80% AFUE, the GPGM32404031 is an inexpensive option with a standard efficiency designed for rooftop and next-to-building applications.
Features
- 2 ton, 40,000 BTU packaged unit
- 13.4 SEER2, 80% AFUE
- Downflow or horizontal discharge installation options
- Fully charged and ready to install
- Low sound output
- Low NOx compliant
Specifications
| SKU | GPGM32404031 |
|---|---|
| Weight (in lbs) | 412.000000 |
| AHRI Certificate Number | 209319520 |
| Brand/Manufacturer | Goodman |
| Replaces | GPU1424040M41, GPG1424040M41, 663051662322 |
| Furnace Efficiency / AFUE | 80% |
| Cooling BTU | 23,000 BTU |
| Heating BTU | 40,000 BTU |
| Blower Motor | Multi-Speed |
| Maximum CFM | 800 |
| Decibel Level (dBA) | 78 decibels |
| Configuration | Downflow/Horizontal |
| Refrigerant | R32 |
| SEER2 (Efficiency) | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size | 35 amps |
| Tonnage | 2 Ton |
| Fuel Type | Natural Gas |
| Height | 34 1/2" |
| Width | 47" |
| Depth | 51" |
Manual
- GPGM3 Specifications Sheet
- GPGM3 Installation Manual
- GPGM3 Replacement Parts Manual
- GPGM3 Service Manual
What our Experts Think
-
Compact 2‑Ton Cooling & Heating
This 24,000 BTU gas pack unit delivers reliable heating and cooling for smaller homes or zones, combining both functions in a single outdoor package. -
Efficient 13.4 SEER2 Performance
Offers energy-efficient cooling while maintaining cost-effective operation for residential use. -
Reliable Single‑Stage Operation
The single-stage compressor provides consistent performance with simple, durable operation for steady indoor comfort. -
Modern R‑32 Refrigerant Technology
Uses R‑32 refrigerant, supporting improved environmental performance and modern HVAC efficiency standards. -
Durable Outdoor Cabinet
Features a galvanized steel cabinet with powder‑coat finish and louvered coil guard to protect internal components from corrosion, debris, and weather. -
Installer-Friendly Features
Includes factory-installed filter drier, service valves, and accessible electrical connections for simplified installation and maintenance. -
Space-Saving All-in-One Design
Combines heating and cooling in a single compact unit, ideal for homes with limited outdoor space or rooftop installations.
Q&A
Q: What size building is this unit suitable for?
A: Delivers 2 tons of cooling (≈24,000 BTU) and 40,000 BTU gas heating, ideal for small to medium homes or light commercial spaces.
Q: How efficient is this packaged HVAC unit?
A: It features 13.4 SEER2 cooling efficiency for energy‑efficient summer performance and ~80‑81% AFUE heating efficiency for cost‑effective winter heat.
Q: What type of refrigerant does it use?
A: Uses R‑32 refrigerant, which has lower global warming potential (GWP) compared with older refrigerants.
Q: What is “packaged unit” mean?
A: This is an all‑in‑one outdoor HVAC system combining both cooling and gas heating in a single cabinet — no separate indoor furnace or air handler required.
Q: What install configurations are supported?
A: Supports horizontal or downflow installation, offering flexible placement on rooftops or slab mounts.
Q: What kind of compressor and airflow does it use?
A: It uses a single‑stage scroll compressor with a multi‑speed ECM blower motor for reliable, consistent performance.
Q: What are the electrical requirements?
A: Operates on 208/230V single‑phase power (60 Hz) typical for residential packaged HVAC installations.
Q: How loud is the unit during operation?
A: Runs around 78 dBA, comparable to many residential HVAC packaged units.
Q: Does it comply with environmental and safety standards?
A: Yes — it’s AHRI‑certified, ETL listed, and meets Ultra‑Low NOx emissions standards in many regions.
Maintenance Tips
-
Replace or clean air filters every 1–3 months to maintain airflow and system efficiency.
-
Keep the outdoor unit clear of debris, leaves, and vegetation for proper airflow.
-
Maintain 2–3 feet of clearance around the unit to prevent overheating.
-
Inspect the condensate drain line regularly to avoid clogs and water damage.
-
Check refrigerant lines and insulation for wear or leaks.
-
Ensure vents and registers inside the home are unobstructed.
-
Listen for unusual noises like rattling or humming, indicating potential mechanical issues.
-
Check thermostat settings and operation to ensure proper heating and cooling cycles.
-
Clean coil surfaces and blower components periodically for optimal efficiency.
-
Schedule annual professional service to inspect burners, heat exchanger, refrigerant, and electrical components.