Goodman - 2.5 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14 SEER2 - R32 - GLXS3BN3010 / CHPTA3026B3 / GMVC800604BN
Goodman - 2.5 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14 SEER2 - R32 - GLXS3BN3010 / CHPTA3026B3 / GMVC800604BN
Couldn't load pickup availability
Goodman - 2.5 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14 SEER2 - R32 - GLXS3BN3010 / CHPTA3026B3 / GMVC800604BN
Goodman - 2.5 Ton/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Horizontal - 14 SEER2 - R32 - GLXS3BN3010 / CHPTA3026B3 / GMVC800604BN
A Goodman gas furnace and air conditioner system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman gas furnace and air conditioner system is the perfect choice for all of your heating and cooling needs.
Features
- Ideal size to cover a medium-sized house
- 2.5 ton, 13.4 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed filter drier
- 2.5 ton horizontal evaporator coil
- Can be used with heat pump and AC-only condensers
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
- Factory-installed TXV kit
- This furnace is ideal to heat a medium-sized house (in average climate conditions)
- 60,000 BTU 80% AFUE two stage variable speed natural gas furnace
- Requires metal flue venting
- Can be used in the upflow or horizontal orientation
- Can be converted to propane with an LP conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
Specifications
| SKU | GLXS3BN3010 |
|---|---|
| Weight | 149.000000 |
| Manufacturer | Goodman |
| Replaces | Add GSX130301 and GSXN3N3010 |
| Product Features | New Refrigerant Compliant |
| Cooling BTU | 30,000 |
| Decibel Level (dBA) | 74 |
| Horsepower | 1/8 HP |
| Refrigerant | R32 |
| SEER2 | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size | 25 Amps |
| Min. Breaker Size | 14.7 Amps |
| Tonnage | 2.5 Ton |
| Connection | Sweat |
| Height | 32 1/2" |
| Width | 26" |
| Depth | 26" |
Owner's Manual
- GLXS3B Specifications
- GLXS3B Installation Manual
- Warranty Information
- CHPTA Installation Manual
- CHPTA Specifications Sheet
What our Experts Think
-
Balanced heating & cooling for medium homes: This system pairs a 2.5 ton R‑32 condenser with a 60,000 BTU 80 % AFUE gas furnace, delivering dependable year‑round comfort for small to medium residential spaces without oversizing.
-
Solid seasonal performance: With about 14 SEER2 cooling efficiency and 80 % furnace AFUE, it provides above‑average cooling and reliable heating performance at a competitive value point—great for everyday comfort without paying for top‑tier efficiency.
-
R‑32 refrigerant for modern compliance: The GLXS3BN3010 uses R‑32 refrigerant, meeting updated environmental standards while improving cooling effectiveness versus older refrigerants.
-
Precise and efficient refrigerant flow: The CHPTA3026B3 evaporator coil with factory‑installed TXV enhances refrigerant control, boosting cooling responsiveness and helping with humidity control.
-
Durable and flexible horizontal design: All components are AHRI certified and designed for horizontal or multi‑position installation, fitting attics, crawl spaces, or tight utility rooms with ease.
-
Trusted blower and control setup: The GMVC800604BN gas furnace includes a multi‑speed ECM blower, offering smoother airflow and quieter operation compared with basic PSC motors.
-
Peace of mind with warranty: Goodman’s standard 10‑year limited parts warranty plus lifetime heat exchanger coverage (with registration) supports long‑term reliability and value.
-
Great value HVAC choice: Experts see this package as a cost‑effective, well‑rounded mid‑efficiency HVAC solution combining proven components, modern refrigerant tech, and balanced comfort for typical residential installation
Q&A
Q: What type of HVAC system is included?
A: This is a complete Goodman 2.5-ton HVAC system, featuring a 14 SEER2 air conditioner (GLXS3BN3010), cased evaporator coil (CHPTA3026B3), and 60,000 BTU 80% AFUE gas furnace (GMVC800604BN) for reliable year-round heating and cooling.
Q: What size home is this system suitable for?
A: A 2.5-ton AC system (30,000 BTU) is typically ideal for medium homes around 1,200–1,600 sq. ft., depending on insulation, ceiling height, and climate conditions.
Q: How energy efficient is this system?
A: The system provides 14 SEER2 cooling efficiency and an 80% AFUE gas furnace, converting most fuel into usable heat while delivering reliable comfort.
Q: What refrigerant does the air conditioner use?
A: The condenser uses R‑32 refrigerant, a modern, energy-efficient refrigerant designed to reduce environmental impact.
Q: Does the furnace include advanced features?
A: Yes. The GMVC800604BN furnace has a variable-speed ECM blower motor and two-stage gas valve for quieter operation, consistent airflow, and precise indoor temperature control.
Q: Can this system be installed horizontally?
A: Yes. Both the furnace and coil support horizontal installation, making them suitable for attics, crawl spaces, or other tight installation areas.
Q: What components are included in this HVAC package?
A: This system includes:
-
GLXS3BN3010 – 2.5 Ton 14 SEER2 outdoor AC condenser
-
CHPTA3026B3 – 2.5 Ton cased evaporator coil
-
GMVC800604BN – 60,000 BTU 80% AFUE variable-speed gas furnace
Maintenance Tips
-
Replace air filters every 1–3 months: Maintains airflow, protects the blower, and improves indoor air quality.
-
Keep the outdoor condenser clear: Maintain 2–3 ft clearance and remove leaves, debris, or grass for efficient cooling.
-
Inspect evaporator coil and drain pan: The CHPTA aluminum coil should be checked for dirt or clogs to prevent water leaks and reduce cooling efficiency.
-
Check refrigerant line insulation: Ensure suction line insulation is intact to maintain energy efficiency.
-
Keep vents and registers unobstructed: Ensures balanced airflow and consistent comfort throughout your home.
-
Schedule annual professional service: A certified HVAC technician should inspect the furnace heat exchanger, blower motor, refrigerant levels, and safety controls yearly.
-
Maintain a clear furnace area: Clear surrounding space to allow safe operation and proper airflow for the 80% AFUE gas furnace.
