Goodman - 2.5 Ton/30,000 BTU - Multi-Positional - Heat Pump Split System - 15.2 SEER2 - R32 GLZS5BA3010
Goodman - 2.5 Ton/30,000 BTU - Multi-Positional - Heat Pump Split System - 15.2 SEER2 - R32 GLZS5BA3010
Couldn't load pickup availability
Goodman - 2.5 Ton/30,000 BTU - Multi-Positional - Heat Pump Split System - 15.2 SEER2 - R32 GLZS5BA3010
Goodman - 2.5 Ton/30,000 BTU - Multi-Positional - Heat Pump Split System - 15.2 SEER2 - R32 GLZS5BA3010
The Goodman Heat Pump Split System is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, the Goodman Heat Pump Split System is a perfect choice for all of your heating and cooling needs.
Features
- Designed to cover a smaller house in average climates
- 2.5 Ton, 15.2 SEER2 heat pump condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed bi-flow filter drier
-
Air Handler
- 2.5 ton air handler
- Electric heat compatible
- Optimized for use with R-32 refrigerant
- Multi-speed, direct drive ECM blower motor
- Multi-positional (upflow, downflow, or horizontal)
Specifications
| SKU | GLZS5BA3010 |
|---|---|
| Weight | 235.000000 |
| Manufacturer | Goodman |
| Replaces | GSZ160301 |
| Cooling BTU | 30,000 |
| Heating BTU | 30,000 |
| Blower Motor | Single Speed Motor |
| Decibel Level (dBA) | 69 |
| Horsepower | 0.167 HP |
| Refrigerant | R32 |
| SEER2 | 15.2 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Electrical | 208/230v 1 Phase 60Hz |
| Max Breaker Size | 30 Amps |
| Min. Breaker Size | 18.6 Amps |
| Tonnage | 2.5 Ton |
| Connection | Sweat |
| Height | 39 1/2" |
| Width | 35 1/2" |
| Depth | 35 1/2" |
Manual
- GSZH5 Installation Manual
- GSZH5 Specifications Sheet
- AMST Installation Manual
- AMST Specifications Sheet
What our Experts Think
-
High Efficiency: SEER2 15.2 provides energy savings while maintaining strong cooling.
-
Right-Sized Capacity: 2.5 Ton / 30,000 BTU ideal for medium-sized homes or spaces.
-
Multi-Positional Design: Flexible installation options for upflow, downflow, or horizontal setups.
-
Reliable Performance: Engineered for consistent, dependable operation.
-
Eco-Friendly Refrigerant: Uses R32 to minimize environmental impact.
-
Quiet Operation: Optimized for low operational noise.
-
Year-Round Comfort: Integrates efficiently into a heat pump system for heating and cooling.
Q&A
Q: What cooling and heating capacity does this system deliver?
A: This split system delivers 30,000 BTU (2.5 tons) of both cooling and heating performance — suitable for medium‑sized homes when paired with a compatible indoor air handler.
Q: How efficient is this heat pump?
A: It is rated 15.2 SEER2, offering energy‑efficient cooling and effective heating that can help lower utility costs compared with older systems.
Q: What refrigerant does it use?
A: Uses R‑32 refrigerant, a lower‑GWP, more environmentally responsible refrigerant that meets current emissions standards.
Q: What type of compressor does the system have?
A: It features a single‑stage scroll compressor designed for reliable, consistent year‑round performance.
Q: What are the key durability and service features?
A: Includes factory‑installed suction‑line accumulator, crankcase heater, high‑capacity muffler, pressure switches, easy‑access service valves, and a robust galvanized steel cabinet for long‑lasting performance.
Q: What electrical requirements does it need?
A: Operates on 208/230 V single‑phase power, typical for residential heat pump installations.
Q: How loud is the unit during operation?
A: Runs at about 73 dBA, a competitive sound level for outdoor heat pump systems.
Q: What installation configurations are supported?
A: The system can be paired with multi‑positional indoor air handlers (upflow/downflow/horizontal) for flexible installation options.
Q: What safety and compliance certifications does it have?
A: It is AHRI‑certified and ETL‑listed, ensuring tested performance and safety compliance.
Maintenance Tips
-
Clean the outdoor condenser coil regularly to remove dirt, leaves, and debris for optimal efficiency.
-
Maintain 2–3 feet of clearance around the outdoor unit to ensure proper airflow.
-
Replace or clean indoor air filters every 1–3 months to maintain airflow and system performance.
-
Inspect refrigerant lines and insulation for damage or leaks.
-
Keep the condenser fan and top grille clear of debris to prevent airflow restriction.
-
Check the condensate drain line regularly to prevent clogs and water buildup.
-
Ensure thermostat is functioning properly and set for efficient heating/cooling cycles.
-
Listen for unusual noises such as rattling, buzzing, or squealing that may indicate mechanical issues.
-
After storms or strong winds, inspect the outdoor unit for debris or damage.
-
Schedule annual professional HVAC maintenance to inspect refrigerant levels, electrical components, and overall system performance.
