Goodman - 2.5 Ton/30,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA3010
Goodman - 2.5 Ton/30,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA3010
Couldn't load pickup availability
Goodman - 2.5 Ton/30,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA3010
Goodman - 2.5 Ton/30,000 BTU Heat Pump Condenser- SEER2 14.3 - Single Stage - R32 - GLZS4BA3010
The Goodman GLZS4BA3010 heat pump condenser is a standard efficiency, low-cost solution for an all-electric home when paired with a suitable heat pump coil or air handler. Just like all of Goodman's equipment, the GLZS4BA3010 is manufactured with high-quality materials to provide a superior comfort in your home.
Please note this is an outdoor unit only, for full system operation this needs to be paired with an indoor unit.
Features
- Ideal size to cover a smaller house in ideal climates
- 2.5 ton, 14.3 SEER2 heat pump condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Low sound output
- Fully charged for up to 15' of line set
- Factory-installed bi-flow filter drier
Specifications
| 2.5 Ton 14.3 SEER2 Goodman Heat Pump - R32 | |
|---|---|
| SKU | GLZS4BA3010 |
| Weight (in lbs) | 190.000000 |
| Brand/Manufacturer | Goodman |
| Replaces | GSZ140301, GSZB403010 |
| HSPF2 | 7.8 |
| Cooling BTU | 30,000 |
| Heating BTU | 30,000 |
| Blower Motor | Single Speed PSC Motor |
| Decibel Level (dBA) | 77 |
| Horsepower | 1/6 HP |
| Refrigerant | R32 |
| SEER2 (Efficiency) | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208/230v 1 Phase 60 Hz |
| Max Breaker Size | 25 Amps |
| Min. Breaker Size | 15.0 Amps |
| Tonnage | 2.5 Ton |
| Connection | Sweat |
| Height | 39 1/2" |
| Width | 29" |
| Depth | 29" |
Manual
What our Experts Think
-
Balanced Seasonal Comfort with R‑32 Refrigerant
The Goodman GLZS4BA3010 2.5 Ton Heat Pump Condenser delivers 30,000 BTU cooling and heating capacity with 14.3 SEER2 and ~7.8 HSPF2 efficiency, offering reliable year‑round comfort and modern R‑32 refrigerant compliance for lower environmental impact. -
Single‑Stage Reliability
Its single‑stage rotary compressor provides consistent performance and straightforward operation—ideal for homeowners who want dependable heating & cooling without complexity. -
Quiet & Weather‑Ready Outdoor Build
With a 77 dB sound level, heavy‑gauge galvanized‑steel cabinet and removable grille design, the unit is built to withstand outdoor conditions while minimizing noise and corrosion. -
SmartShift® Defrost & Protective Features
SmartShift® technology ensures quiet, reliable defrost cycles in heat mode, while factory‑installed components like high‑capacity muffler, accumulator, and filter drier protect the system and enhance durability. -
Installer‑Friendly Connections
Service valves with easy access to gauge ports, sweat connections, and fully‑enclosed contactor with lug connection help HVAC pros complete installations and maintenance more efficiently.
Q&A
Q1: What type of HVAC unit is this?
A: The Goodman GLZS4BA3010 is a 2.5 ton heat pump condenser designed for year‑round heating and cooling in split‑system installations. It must be paired with a compatible indoor coil or air handler.
Q2: What efficiency ratings does it have?
A: It delivers 14.3 SEER2 cooling efficiency and ~7.8 HSPF2 heating performance, offering balanced comfort and energy savings.
Q3: Which refrigerant does this heat pump use?
A: This model uses R‑32 refrigerant, a modern, lower‑environmental‑impact refrigerant with improved energy performance.
Q4: What kind of compressor and operation does the unit use?
A: It features a single‑stage rotary compressor with a single‑speed PSC condenser fan motor for reliable, consistent operation.
Q5: What key protective features are included?
A: The unit includes factory‑installed filter drier, suction‑line accumulator, crankcase heater, high‑capacity muffler, and high/low‑pressure switches to help improve durability and performance.
Q6: What cabinet and build features does it have?
A: Built with a heavy‑gauge galvanized‑steel cabinet, removable grille top, and steel louver coil guard with a durable architectural gray finish — rated to resist corrosion and meet structural wind requirements when anchored.
Q7: What are typical dimensions and sound levels?
A: Approximate size is 29" W × 29" D × 39.5" H, with typical sound levels around 77 dBA during operation.
Maintenance Tips
-
Keep Outdoor Coil Clean – Regularly remove leaves, grass, and dirt from the condenser fins and wash gently with a hose (inside‑out) to maintain efficiency; avoid pressure washers that can bend fins.
-
Maintain Proper Airflow Around Unit – Ensure at least ~18–24″ clearance at sides and ~36″ in front so airflow isn’t restricted.
-
Check Electrical Connections Annually – Inspect contactor, capacitor and wiring for loose or corroded connections that can reduce performance or cause failures.
-
Clear Drainage and Pad Area – Make sure the unit base is level and that water drains away from the pad to avoid corrosion and flooding around the condenser.
-
Inspect Refrigerant Lines – Ensure R32 refrigerant lines are properly insulated and leak‑free; low charge reduces heating/cooling effectiveness.
-
Annual HVAC Professional Service – Have a licensed technician check refrigerant levels, clean coils, test defrost operation, and verify the heat pump’s SEER2 performance