Goodman - 2.5 Ton/30,000 BTU Air Conditioner Condenser - SEER2 14.3 - Single Stage - R32 - GLXS4BA3010
Goodman - 2.5 Ton/30,000 BTU Air Conditioner Condenser - SEER2 14.3 - Single Stage - R32 - GLXS4BA3010
Couldn't load pickup availability
Goodman - 2.5 Ton/30,000 BTU Air Conditioner Condenser - SEER2 14.3 - Single Stage - R32 - GLXS4BA3010
Goodman - 2.5 Ton/30,000 BTU Air Conditioner Condenser - SEER2 14.3 - Single Stage - R32 - GLXS4BA3010
The Goodman brand has been focused on providing efficiency and comfort where it matters most while still being an inexpensive brand. With its superior components and a standard efficiency, the Goodman GLXS4BA3010 air conditioner condenser is a popular choice for homeowners around the United States.
Features
- Ideal size to cover a small house in ideal climates
- 2.5 ton, 14.3 SEER2 AC-only condenser
- R32: Complies with Clean Air Act New Refrigerant Requirements
- Fully charged for up to 15' of line set
- Low sound output
- Factory-installed filter drier
Specifications
| 3.5 Ton 14.3 SEER2 Goodman Air Conditioner Condenser | |
|---|---|
| SKU | GLXS4BA4210 |
| Weight (in lbs) | 248.000000 |
| Brand/Manufacturer | Goodman |
| Replaces | GSX140421 |
| Cooling BTU | 42,000 |
| Blower Motor | Single Speed PSC Motor |
| Decibel Level (dBA) | 71 |
| Horsepower | 0.167 HP |
| Refrigerant | R32 |
| SEER2 (Efficiency) | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Electrical | 208/230v 1 Phase 60Hz |
| Max Breaker Size | 40 Amps |
| Min. Breaker Size | 23.1 Amps |
| Tonnage | 3.5 Ton |
| Connection | Sweat |
| Height | 39 1/2" |
| Width | 35 1/2" |
| Depth | 35 1/2" |
Manual
What our Experts Think
-
Efficient Everyday Cooling with R‑32 Refrigerant
The Goodman GLXS4BA3010 2.5 Ton AC Condenser delivers 30,000 BTU cooling with a 14.3 SEER2 rating, providing solid seasonal energy efficiency while using R‑32 refrigerant for lower global warming impact compared with older systems. -
Steady Single‑Stage Performance
Its single‑stage scroll/rotary compressor offers consistent, dependable operation—ideal for homeowners who prioritize reliable cooling without the complexity of multi‑stage or inverter systems. -
Quiet, Durable Outdoor Design
Built with a heavy‑gauge steel cabinet and factory‑installed condenser components (filter drier, service valves, venturi airflow), this unit emphasizes long‑term durability and quieter performance in residential settings. -
Ready for Installation & Service‑Friendly
Ships fully charged for up to ~15 ft of line set and includes easy‑access service ports, helping HVAC pros install and maintain the unit efficiently. -
Matched System Flexibility
Designed to pair with compatible indoor coils and air handlers, this condenser supports common residential split system layouts—giving installers more flexibility in system matching.
Q&A
Q1: What type of HVAC component is this?
A: The Goodman GLXS4BA3010 is a 2.5 ton outdoor air conditioner condenser used in split‑system cooling setups. It must be paired with a compatible indoor coil or air handler.
Q2: What cooling capacity and efficiency does it offer?
A: This unit delivers 30,000 BTU of cooling and has a 14.3 SEER2 rating, offering regulated seasonal energy efficiency for residential applications.
Q3: Which refrigerant does it use?
A: It uses R‑32 refrigerant, a modern, lower‑global‑warming option that supports current environmental standards.
Q4: What kind of compressor and operation does it have?
A: The condenser features a single‑stage compressor with a single‑speed PSC fan motor for straightforward, reliable cool‑only operation.
Q5: What are the key build features?
A: It includes a factory‑installed filter drier, sweat service valves with gauge access, steel louver coil guard, venturi airflow design, and an architectural gray powder‑coat cabinet for durability and outdoor protection.
Q6: What are the electrical and connection specs?
A: Operates on 208/230 V single‑phase power, with 3/8″ liquid and 3/4″ suction line connections, and 15–25 A circuit protection recommended.
Q7: How big is this condenser?
A: Typical dimensions are approximately 29″ W × 29″ D × 32″ H, making it compatible with standard residential condenser pads.
Maintenance Tips
-
Replace or Clean Indoor Filters Regularly – Change filters every 1–3 months to maintain strong airflow and reduce strain on the condenser.
-
Keep Outdoor Unit Clear of Debris – Trim grass, remove leaves, sticks, and vegetation around the condenser to ensure unobstructed airflow and efficient heat rejection.
-
Clean Condenser Coils Annually – Dirt and dust on the copper/aluminum coils reduce efficiency; use a soft brush or gentle hose rinse, or have a pro clean coils yearly.
-
Check Fan Blades & Components – Inspect fan blades for damage and clear any debris; ensure the condenser fan runs smoothly during cooling cycles.
-
Inspect Refrigerant Lines & Connections – A technician should check R32 refrigerant levels and insulation to maintain optimal SEER2 cooling performance.
-
Verify Electrical Connections Annually – Have a pro tighten connections and inspect capacitors and contactors to reduce risk of faults.
-
Annual Professional Tune‑Up – Schedule a yearly HVAC service before cooling season to check pressures, electrical, and overall condenser health.