Goodman - 100,000 BTU 96% Gas Furnace - 21" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GR9T961004CN
Goodman - 100,000 BTU 96% Gas Furnace - 21" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GR9T961004CN
Couldn't load pickup availability
Goodman - 100,000 BTU 96% Gas Furnace - 21" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GR9T961004CN
Goodman - 100,000 BTU 96% Gas Furnace - 21" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GR9T961004CN
As a high-efficiency system, the GR9T961004CN Goodman gas furnace features many money saving features. The two-stage, 9-speed furnace uses a superior heat exchanger for better heat transfers to your home. Considered one of the best efficiencies on the market, the GR9T961004CN is a good way to go if you want to lower your gas bill.
Features
- This furnace is ideal to heat a larger house (depending on climate)
- 100,000 BTU 96% AFUE natural gas furnace
- Requires plastic/PVC flue venting
- Complies with Clean Air Act New Refrigerant Requirements
- Can be used in the upflow or horizontal orientation
- Can be converted to an LP furnace with an optional conversion kit (sold separately)
- Innovative design for electrical efficiency, safety, and lower sound output
Specifications
| Goodman 96% 100,000 BTU Two Stage Gas Furnace - 21" Width - Upflow / Horizontal | |
|---|---|
| SKU | GR9T961004CN |
| Weight (in lbs) | 140.000000 |
| AHRI Certificate Number | 215225029 |
| Airflow Direction | Upflow/Horizontal |
| Exhaust Flue Requirement | Plastic / PVC |
| R-32 Compliant | Yes |
| Brand/Manufacturer | Goodman |
| Product Features | New Refrigerant Compliant |
| Furnace Efficiency / AFUE | 96% |
| Heating BTU | 100,000 |
| Blower Motor | 9 Speed - ECM |
| Maximum CFM | 1600 |
| Configuration | Upflow/Horizontal |
| Energy Star | Yes |
| Electrical | 115 V. 1 Phase 60 Hz |
| Max Breaker Size | 25 Amps |
| Min. Breaker Size | 14.4 Amps |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 34.5" |
| Width | 21" |
| Depth | 28.75" |
Manual
What our Experts Think
-
High‑Efficiency Heating Performance: With a 96 % AFUE rating, this two‑stage gas furnace converts nearly all fuel into usable heat—reducing energy waste and lowering utility costs compared to standard 80 % models.
-
Powerful 100,000 BTU Output: Offers 100,000 BTU input (96,000 BTU output) capacity, making it well‑suited for larger homes or high‑demand heating zones.
-
Two‑Stage Gas Valve for Comfort: The two‑stage burner adjusts heating output based on demand—providing quieter operation, fewer temperature swings, and more consistent indoor comfort.
-
Advanced Multi‑Speed ECM Blower: A 9‑speed ECM blower motor optimizes airflow for improved efficiency, lower energy consumption, and quieter circulation throughout your home.
-
Durable, Reliable Construction: Heavy‑gauge insulated cabinet, aluminized steel primary and stainless‑steel secondary heat exchangers, and a silicon nitride ignitor enhance long‑term reliability.
-
Flexible Installation Options: Supports upflow or horizontal configuration, fitting into a variety of mechanical spaces from basements to closets.
-
Service‑Friendly Features: Self‑diagnostic control board, color‑coded terminals, and easy access simplify troubleshooting, installation, and maintenance.
Q&A
Q: What heating capacity and efficiency does this Goodman furnace deliver?
A: The Goodman GR9T961004CN provides 100,000 BTU input (≈96,000 BTU output) with a 96% AFUE efficiency, converting nearly all fuel into usable heat to reduce energy waste and lower heating costs.
Q: What type of gas valve and stages does it feature?
A: It includes a two‑stage gas valve, allowing the furnace to run at reduced capacity during milder weather and at full capacity when needed for maximum comfort.
Q: What blower motor does the furnace use?
A: The unit is equipped with a multi‑speed ECM blower motor (9‑speed), delivering efficient, quieter airflow and improved heating performance.
Q: What installation orientations are supported?
A: Designed for upflow or horizontal (left/right) installation, giving flexibility for basements, attics, or closets.
Q: What electrical and venting requirements are there?
A: Operates on standard 115 V single‑phase power and — as a high‑efficiency condensing furnace — requires plastic/PVC flue venting.
Q: What durability and performance features are included?
A: Features include stainless steel secondary heat exchanger, silicon nitride igniter, heavy‑gauge insulated cabinet, self‑diagnostic control board, and low‑speed fan options for quiet circulation.
Q: What fuel types is it compatible with?
A: Factory configured for natural gas and can be converted to propane (LP) with an optional conversion kit.
Maintenance Tips
-
Replace or clean air filters every 1–3 months to maintain airflow and prevent dust buildup on the heat exchanger and blower.
-
Inspect the heat exchanger annually for cracks or corrosion to ensure safe and efficient operation.
-
Clean burners, pilot assembly, and ignition system for reliable two-stage combustion.
-
Check the blower motor and fan assembly for dust, debris, and lubrication needs.
-
Inspect venting and flue pipe for obstructions or leaks to ensure safe exhaust of combustion gases.
-
Test gas valves, two-stage operation, and thermostat for accurate temperature control.
-
Verify 115V electrical connections and inspect wiring for wear or corrosion.
-
Keep surrounding area clear to maintain airflow and reduce fire hazards.
-
Schedule annual professional HVAC service for full inspection, cleaning, and safety testing.