Features
-
Value kit includes a PowerMark Gold 200 Amp main breaker indoor circuit breaker panel, 10 20 Amp single pole, 1 30 Amp double pole, 1 50 Amp double pole THQL 1 in circuit breakers
-
Main breaker is factory installed
-
Galvanized box for rust resistance with a self-adjusting dead-front cover
-
Copper buss for increased conduction
-
Full-length neutral bars for faster and easier wiring and 100% split neutral holes on each side are rated for #14-4 wire
-
Single-phase, 3-wire, 120/240 VAC, 22,000 AIC rating
-
Compatible with GE THQL, THQP, GFCI and AFCI circuit breakers
-
Meets UL and ANSI safety requirements
What our Experts Think
-
High-capacity 200A residential power center
Designed for modern homes needing strong, reliable electrical distribution with support for heavy appliance loads and future expansion. -
32-space / 40-circuit efficient layout
Offers excellent breaker density, allowing multiple dedicated circuits while maintaining organized wiring and service access. -
Indoor NEMA 1 protected installation
Intended for interior use such as garages, basements, or utility rooms where environmental exposure is controlled. -
Factory-installed main breaker safety
Integrated 200-amp main breaker ensures built-in overcurrent protection and simplifies installation for service entrances or subpanel setups. -
Compatible with modern breaker systems
Supports GE THQL/THQP breakers including AFCI and GFCI options for current electrical code compliance and upgrades. -
Streamlined wiring design
Full-length neutral bars and structured interior layout improve installation speed and reduce maintenance complexity. -
Trusted PowerMark Gold platform
Widely used in residential electrical upgrades for its reliability, availability, and contractor-friendly design.
Q&A
Q: What is the GE PowerMark Gold 200-Amp 32-Space 40-Circuit Indoor Main Breaker Load Center used for?
A: A residential main electrical panel that distributes 120/240V power throughout a home and supports multiple branch circuits.
Q: Is this a main breaker or subpanel?
A: It is a main breaker load center with a factory-installed 200A main disconnect, suitable as the primary service panel.
Q: How many circuits does it support?
A: It provides 32 spaces / 40 circuits, allowing tandem breakers for expanded wiring capacity.
Q: Is it designed for indoor use?
A: Yes. It has a NEMA 1 indoor-rated enclosure, intended for interior installation only.
Q: What electrical system does it support?
A: It is designed for single-phase, 3-wire, 120/240V residential systems commonly used in homes.
Q: Is it compatible with modern breakers?
A: Yes. It works with GE THQL, THQP, AFCI, and GFCI breakers, supporting updated electrical code requirements.
Q: What are its build and safety features?
A: It includes a galvanized steel enclosure, copper bus bars, and UL listing for safety and durability.
Q: Where is it typically used?
A: Common in homes, garages, and residential upgrades where a high-capacity, organized breaker panel is needed.
Maintenance Tips
- Keep panel dry & clean: Install in a low-humidity indoor area; avoid dust buildup inside enclosure.
- Maintain clear access: Ensure at least 3 feet of workspace in front of the panel at all times.
- Check connections periodically: Have a licensed electrician inspect and tighten lugs, neutrals, and grounds.
- Prevent overloads: Stay within 200-amp rating and 40-circuit capacity to avoid overheating risks.
- Inspect breakers: Replace any breakers showing heat damage, frequent tripping, or corrosion.
- Keep cover secure: Ensure the panel door closes properly to protect internal components.
- Update labeling: Maintain accurate circuit directory for faster, safer troubleshooting.