The Cooper & Hunter 6-Zone Mini Split System features a 60,000 BTU capacity, 22 SEER2 efficiency, and built-in Wi-Fi control for seamless temperature management across six zones. It includes the CH-R60MES-230VO outdoor unit, uses R454B refrigerant, and operates effectively in heating conditions as low as -13°F.
Features
- 6-zone system — the CH-R60MES-230VO outdoor unit supports up to 6 independently controlled indoor units; port adapters included, no branch boxes required
- 60,000 BTU nominal system capacity across 6 zones, each on its own remote
- 22 SEER2 inverter efficiency — current R454B generation
- Heat pump — heats down to -13°F outdoor ambient
- R454B refrigerant, factory pre-charged; built-in Wi-Fi control
- Mix any Cooper & Hunter head types — wall mount, ceiling cassette, slim duct, floor/ceiling console
- Outdoor unit (condenser): CH-R60MES-230VO — 60000 BTU R454B multi-zone outdoor unit
- Up to 6 indoor units — configured to your selected zones (wall-mount, cassette, slim-duct, or console), each with a remote control
- Line-set kits — choose copper line-set length per zone at checkout (or supply your own)
Specifications
| Power Supply | 208/230V, 1 Ph, 60 Hz (voltage range 187-253V) |
|---|---|
| Cooling — Rated Capacity (Range) | 60,000 Btu/h (19,000–62,000) |
| Heating at 47°F — Rated Capacity (Range) | 60,000 Btu/h (20,000–60,000) |
| Rated Heating at 5°F | 39,000 Btu/h |
| SEER2 / EER2 | 22 / 10 |
| HSPF4 / HSPF5 / COP (47°F) | 9.5 / 7.4 / 3.7 |
| Outdoor Unit MCA / Max. Fuse | 36 A / 40 A |
| Max. Connectable Indoor Units | 6 |
| Outdoor Noise Level | 65 dB(A) |
| Outdoor Unit Dimensions (W×D×H) | 37.48 × 16.34 × 52.48 in |
| Outdoor Unit Net / Gross Weight | 237.88 / 270.28 lbs |
| Refrigerant Type / Charge | R454B / 151.68 oz |
| Pre-charged Line Length | 150 ft (add 0.16 oz/ft for 1/4 in liquid pipe / 0.32 oz/ft for 3/8 in liquid pipe) |
| Max. Total Pipe Length / Max. to One Indoor | 262.4 ft / 114.8 ft |
| Max. Height Difference (Indoor–Outdoor / Between Indoors) | 49.2 ft / 33 ft |
| Operating Range — Cooling / Heating | -13–122°F / -13–75°F outdoor ambient |
What our Experts Think
- True 6-Zone Comfort – This 60,000 BTU system pairs six 6,000 BTU concealed duct units, allowing independent temperature control in up to six smaller rooms while keeping the equipment hidden above ceilings.
- Clean, Hidden Installation – Concealed duct air handlers provide discreet comfort with only supply and return grilles visible, making them ideal for modern homes and offices.
- High-Efficiency Inverter Technology – Variable-speed inverter operation delivers stable temperatures, quieter performance, and lower energy consumption than conventional systems.
- Eco-Friendly R454B Refrigerant – Uses next-generation R454B refrigerant for efficient heating and cooling with reduced environmental impact.
- Year-Round Performance – Heat pump technology provides reliable cooling in summer and dependable heating in cold weather, making it a complete all-season solution.
- Expert Verdict – An excellent choice for luxury homes or light commercial spaces needing hidden ducted climate control, individualized room comfort, and efficient multi-zone operation.
Q&A
Q: What is included in this multi-zone system?
A: This 60,000 BTU system includes six concealed duct indoor units, each rated at 6,000 BTU, for discreet whole-home comfort.
Q: Can each zone be controlled independently?
A: Yes. Each indoor unit has independent temperature control, allowing customized comfort in every zone.
Q: Does this system provide both heating and cooling?
A: Yes. The heat pump system delivers efficient year-round heating and cooling.
Q: What refrigerant does this system use?
A: It uses R454B refrigerant for improved efficiency and a lower environmental impact.
Q: Why choose concealed duct indoor units?
A: Concealed duct units are hidden above ceilings or in soffits, providing quiet operation and a clean, built-in appearance while distributing air through ductwork.
Maintenance Tips
- Clean the washable air filters every 2–4 weeks to maintain optimal airflow, heating, and cooling efficiency.
- Keep the indoor units and outdoor condenser free of dust, leaves, and debris to ensure reliable performance and proper airflow.
- Wipe the indoor units with a soft, damp cloth and avoid abrasive cleaners or harsh chemicals that may damage the finish.
- Inspect condensate drain lines regularly to prevent clogs, leaks, and water damage.
- Schedule annual professional maintenance to inspect refrigerant levels, electrical connections, and overall system performance for maximum efficiency.