Cooper & Hunter 6 Zone 48,000 BTU One-Way Cassette Mini Split AC R454B 6K+9K+9K+12K+12K+12K - CH-R48MES-230VO06MCT1W09MCT1W09MCT1W12MCT1W12MCT1W12MCT1W
Cooper & Hunter 6 Zone 48,000 BTU One-Way Cassette Mini Split AC R454B 6K+9K+9K+12K+12K+12K - CH-R48MES-230VO06MCT1W09MCT1W09MCT1W12MCT1W12MCT1W12MCT1W
Couldn't load pickup availability
Cooper & Hunter 6 Zone 48,000 BTU One-Way Cassette Mini Split AC R454B 6K+9K+9K+12K+12K+12K - CH-R48MES-230VO06MCT1W09MCT1W09MCT1W12MCT1W12MCT1W12MCT1W
Cooper & Hunter 6 Zone 48,000 BTU One-Way Cassette Mini Split AC R454B 6K+9K+9K+12K+12K+12K - CH-R48MES-230VO06MCT1W09MCT1W09MCT1W12MCT1W12MCT1W12MCT1W
The Cooper & Hunter 6-Zone Mini Split System features a 48,000 BTU capacity, 24 SEER2 efficiency, and built-in Wi-Fi control for seamless temperature management across six zones. It utilizes R454B refrigerant and operates effectively in heating conditions as low as -13°F, ensuring reliable performance in colder climates.
Features
- 6-zone system — the CH-R48MES-230VO outdoor unit supports up to 6 independently controlled indoor units; port adapters included, no branch boxes required
- 48,000 BTU nominal system capacity across 6 zones, each on its own remote
- 24 SEER2 inverter efficiency — current R454B generation
- Heat pump — heats down to -13°F outdoor ambient
- R454B refrigerant, factory pre-charged; built-in Wi-Fi control
- Mix any Cooper & Hunter head types — wall mount, ceiling cassette, slim duct, floor/ceiling console
- Outdoor unit (condenser): CH-R48MES-230VO — 48000 BTU R454B multi-zone outdoor unit
- Up to 6 indoor units — configured to your selected zones (wall-mount, cassette, slim-duct, or console), each with a remote control
- Line-set kits — choose copper line-set length per zone at checkout (or supply your own)
Specifications
| Power Supply | 208/230V, 1 Ph, 60 Hz (voltage range 187-253V) |
|---|---|
| Cooling — Rated Capacity (Range) | 60,000 Btu/h (19,000–62,000) |
| Heating at 47°F — Rated Capacity (Range) | 60,000 Btu/h (20,000–60,000) |
| Rated Heating at 5°F | 39,000 Btu/h |
| SEER2 / EER2 | 22 / 10 |
| HSPF4 / HSPF5 / COP (47°F) | 9.5 / 7.4 / 3.7 |
| Outdoor Unit MCA / Max. Fuse | 36 A / 40 A |
| Max. Connectable Indoor Units | 6 |
| Outdoor Noise Level | 65 dB(A) |
| Outdoor Unit Dimensions (W×D×H) | 37.48 × 16.34 × 52.48 in |
| Outdoor Unit Net / Gross Weight | 237.88 / 270.28 lbs |
| Refrigerant Type / Charge | R454B / 151.68 oz |
| Pre-charged Line Length | 150 ft (add 0.16 oz/ft for 1/4 in liquid pipe / 0.32 oz/ft for 3/8 in liquid pipe) |
| Max. Total Pipe Length / Max. to One Indoor | 262.4 ft / 114.8 ft |
| Max. Height Difference (Indoor–Outdoor / Between Indoors) | 49.2 ft / 33 ft |
| Operating Range — Cooling / Heating | -13–122°F / -13–75°F outdoor ambient |
What our Experts Think
- True 6-Zone Comfort – This 48,000 BTU system combines 6K + 9K + 9K + 12K + 12K + 12K one-way cassette units, providing independent temperature control for up to six rooms.
- Sleek One-Way Cassette Design – Low-profile ceiling-mounted indoor units blend seamlessly into the ceiling, delivering discreet comfort with efficient directional airflow.
- High-Efficiency Inverter Technology – Variable-speed inverter operation automatically adjusts output to maintain stable temperatures while reducing energy consumption.
- Advanced R454B Refrigerant – Uses next-generation R454B refrigerant for efficient heating and cooling with improved environmental performance.
- Year-Round Heat Pump Performance – Provides dependable cooling in summer and reliable heating in colder weather for all-season comfort.
- Expert Verdict – An excellent solution for homes and light commercial spaces that need hidden ceiling-mounted units, personalized multi-zone comfort, and energy-efficient operation.
Q&A
Q: What is included in this mini split system?
A: This 48,000 BTU multi-zone system includes six one-way cassette indoor units (6K+9K+9K+12K+12K+12K) for efficient heating and cooling in multiple rooms.
Q: Can each zone be controlled independently?
A: Yes. Each indoor unit has its own temperature control, allowing personalized comfort in every zone.
Q: Does this system provide both heating and cooling?
A: Yes. The heat pump system delivers reliable year-round heating and cooling.
Q: What refrigerant does this system use?
A: It uses R454B refrigerant, offering improved energy efficiency and a lower environmental impact.
Q: Why choose one-way cassette indoor units?
A: One-way cassette units mount flush in the ceiling, providing a clean, space-saving design with quiet operation and targeted airflow.
Maintenance Tips
- Clean the return air filters every 2–4 weeks to maintain efficient airflow, cooling, and heating performance.
- Keep all indoor cassette units and the outdoor condenser free of dust, leaves, and debris for optimal system efficiency.
- Inspect and clean the condensate drain lines and drain pumps regularly to help prevent clogs, leaks, and water damage.
- Wipe the cassette panels and air outlets with a soft, damp cloth and avoid abrasive or harsh chemical cleaners.
- Schedule annual professional maintenance to inspect refrigerant levels, electrical components, and overall performance across all six zones.
