Cooper & Hunter Hyper 48,000 BTU 6-Zone 6K+9K+9K+9K+9K+9K One-Way Cassette, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump - CH-RHP48M-230VO/M06OW+M09OW+M09OW+M09OW+M09OW+M09OW-NO
Cooper & Hunter Hyper 48,000 BTU 6-Zone 6K+9K+9K+9K+9K+9K One-Way Cassette, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump - CH-RHP48M-230VO/M06OW+M09OW+M09OW+M09OW+M09OW+M09OW-NO
Couldn't load pickup availability
Cooper & Hunter Hyper 48,000 BTU 6-Zone 6K+9K+9K+9K+9K+9K One-Way Cassette, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump - CH-RHP48M-230VO/M06OW+M09OW+M09OW+M09OW+M09OW+M09OW-NO
Cooper & Hunter Hyper 48,000 BTU 6-Zone 6K+9K+9K+9K+9K+9K One-Way Cassette, 230V, R454B - Ductless Mini Split Air Conditioner Heat Pump - CH-RHP48M-230VO/M06OW+M09OW+M09OW+M09OW+M09OW+M09OW-NO
The Cooper & Hunter Hyper Heat 6-Zone Mini Split System features a nominal total BTU of 48,000 and includes six one-way cassette zones, paired with the CH-RHP48M-230VO outdoor unit. It offers a SEER2 rating of 23, heating performance down to -22°F, uses R454B refrigerant, and supports Wi-Fi control for remote operation.
Features
- 6-zone Hyper Heat system — the CH-RHP48M-230VO outdoor unit supports up to 6 independently controlled indoor units
- 48,000 BTU nominal capacity across 6 zones, each on its own remote
- 23 SEER2 inverter efficiency
- Hyper Heat — heats down to -22°F outdoor ambient, for cold climates
- R454B refrigerant, factory pre-charged; Wi-Fi control
- Outdoor unit (condenser): CH-RHP48M-230VO — R454B Hyper Heat multi-zone outdoor unit
- Zone 1 — One-Way Cassette: 6,000 Btu/h indoor unit with remote control
- Zone 2 — One-Way Cassette: 9,000 Btu/h indoor unit with remote control
- Zone 3 — One-Way Cassette: 9,000 Btu/h indoor unit with remote control
- Zone 4 — One-Way Cassette: 9,000 Btu/h indoor unit with remote control
- Zone 5 — One-Way Cassette: 9,000 Btu/h indoor unit with remote control
- Zone 6 — One-Way Cassette: 9,000 Btu/h indoor unit with remote control
- Line-set kits — choose copper line-set length per zone at checkout (or supply your own)
Specifications
| Power Supply | 208/230V, 1 Ph, 60 Hz (voltage range 187-253V) |
|---|---|
| Cooling — Rated Capacity (Range) | 60,000 Btu/h (19,000–62,000) |
| Heating at 47°F — Rated Capacity (Range) | 60,000 Btu/h (20,000–60,000) |
| Rated Heating at 5°F | 39,000 Btu/h |
| SEER2 / EER2 | 22 / 10 |
| HSPF4 / HSPF5 / COP (47°F) | 9.5 / 7.4 / 3.7 |
| Outdoor Unit MCA / Max. Fuse | 36 A / 40 A |
| Max. Connectable Indoor Units | 6 |
| Outdoor Noise Level | 65 dB(A) |
| Outdoor Unit Dimensions (W×D×H) | 37.48 × 16.34 × 52.48 in |
| Outdoor Unit Net / Gross Weight | 237.88 / 270.28 lbs |
| Refrigerant Type / Charge | R454B / 151.68 oz |
| Pre-charged Line Length | 150 ft (add 0.16 oz/ft for 1/4 in liquid pipe / 0.32 oz/ft for 3/8 in liquid pipe) |
| Max. Total Pipe Length / Max. to One Indoor | 262.4 ft / 114.8 ft |
| Max. Height Difference (Indoor–Outdoor / Between Indoors) | 49.2 ft / 33 ft |
| Operating Range — Cooling / Heating | -13–122°F / -13–75°F outdoor ambient |
What our Experts Think
- Advanced multi-zone comfort: The Cooper & Hunter Hyper 48,000 BTU 6-Zone Mini Split system provides efficient heating and cooling for large homes, offices, and commercial spaces with flexible zone control.
- Six-zone configuration: The 6K + 9K + 9K + 9K + 9K + 9K BTU setup allows precise temperature management across multiple rooms while maximizing comfort and efficiency.
- Space-saving one-way cassette design: Ceiling-mounted one-way cassette units offer a clean, low-profile installation while distributing conditioned air evenly throughout the space.
- High-performance inverter technology: The Hyper series is designed for reliable operation, improved efficiency, and consistent temperature control while reducing energy waste.
- Eco-friendly R454B refrigerant: Uses next-generation R454B refrigerant to support improved environmental performance with lower global warming potential.
- Powerful heating and cooling capability: Heat pump functionality provides dependable comfort throughout the year, delivering both cooling and heating from one efficient ductless system.
- Ideal for modern installations: A great solution for new construction, renovations, offices, and properties where traditional ductwork is impractical.
- Expert recommendation: A versatile premium HVAC solution for customers seeking discreet ceiling installation, multiple comfort zones, and efficient year-round climate control.
Q&A
Q: What is the cooling capacity of the Cooper & Hunter Hyper 6-Zone Mini Split System?
A: This system delivers 48,000 BTU of cooling capacity for efficient multi-room heating and cooling.
Q: How many zones does this mini split system support?
A: It supports up to 6 independent zones with six one-way cassette indoor units for customized comfort in multiple rooms.
Q: What indoor units are included in this package?
A: The system includes one-way cassette units configured as 6K+9K+9K+9K+9K+9K BTU for flexible zone control.
Q: Does this system provide both heating and cooling?
A: Yes, it is a ductless mini split heat pump designed for year-round air conditioning and heating performance.
Q: What refrigerant does this Cooper & Hunter mini split use?
A: It uses R454B refrigerant, a modern lower-GWP refrigerant designed for improved environmental performance.
Q: What voltage is required for installation?
A: This system operates on 208-230V, single-phase, 60Hz electrical power.
Q: Is this a ductless mini split air conditioner?
A: Yes, the ductless design provides efficient heating and cooling without requiring traditional ductwork.
Maintenance Tips
- Clean or replace air filters regularly to maintain efficient airflow and indoor air quality.
- Clean cassette panels, vents, and louvers to prevent dust buildup and improve air distribution.
- Keep the outdoor condenser unit free from leaves, dirt, and debris for proper airflow.
- Clean condenser coils periodically to support efficient heating and cooling.
- Inspect refrigerant lines and connections for leaks or signs of damage.
- Check and clear condensate drains to prevent clogs and water leaks.
- Ensure ceiling cassette air outlets remain unobstructed for even temperature control.
- Monitor system performance and unusual noises for early maintenance needs.
- Schedule professional maintenance periodically to improve efficiency and extend system life.
