GOODMAN 2 Ton 13.4 SEER2 96% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9S960603BN
GOODMAN 2 Ton 13.4 SEER2 96% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9S960603BN
Couldn't load pickup availability
GOODMAN 2 Ton 13.4 SEER2 96% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9S960603BN
GOODMAN 2 Ton 13.4 SEER2 96% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9S960603BN
The ACiQ AQ-GLXS3BN2410 is a durable, high-quality condenser unit that is the perfect cooling solution for homes up to 1400 square feet in northern states. At a capacity of 2 tons and a SEER2 rating of 13.4, this cooling-only condenser won’t break the bank while still reliably cooling your home for years to come. Easy to access service valves make installation by a licensed HVAC professional a breeze. Pay for high-end performance without the high-end price tag when you choose ACiQ.
Features
- 13.4 SEER2, 2 tons AC-only Condenser: With a 13.4 SEER2 efficiency rating and a tonnage of 2, this AC condenser is a great choice for smaller homes that experience shorter, milder summers.
- Single Stage: When properly sized and installed, a single stage condenser is a cost-effective and durable option to cool your home.
- R32 Refrigerant: With R32 refrigerant, this unit complies with Clean Air Act refrigerant requirements.
- Fully Charged for up to 15' of Line Set: The condenser comes fully pre-charged with enough refrigerant for up to 15 feet of line set.
Manual
- GLXS3B Specifications
- Installation Manual
- Warranty Information
-
CAPFA Specifications Sheet
- GR9S96 Specifications Sheet
- GR9S96 Installation Manual
What our Experts Think
- High-Efficiency Heating Focused System: Combines a 96% AFUE, 60,000 BTU gas furnace with a 2-ton R32 air conditioner, prioritizing energy-efficient heating with reliable cooling support.
- Exceptional Furnace Efficiency: The 96% AFUE rating significantly reduces wasted fuel, making it a strong choice for lowering winter heating costs.
- Compact Cooling Capacity: The 2-ton, 13.4 SEER2 AC unit is well-suited for smaller homes, apartments, or tightly insulated living spaces.
- Powerful Heating Output: Despite its smaller cooling size, the 60,000 BTU furnace delivers strong and consistent heat for colder regions or higher heating demand.
- Modern R32 Refrigerant: Uses R32 refrigerant, improving efficiency potential and reducing environmental impact compared to older refrigerants.
- Upflow Installation Design: Built for vertical upflow configurations, compatible with basements, utility rooms, closets, and standard residential setups.
- Efficiency-Driven Value System: Best suited for homeowners prioritizing heating savings and long-term efficiency over maximum cooling capacity.
Q&A
Q: What size home is this Goodman 2 Ton HVAC system best suited for?
A: A 2-ton system is typically designed for small to medium homes, depending on insulation, climate, and layout. Proper Manual J load calculation is recommended for accurate sizing.
Q: What efficiency ratings does this system offer?
A: This system combines a 13.4 SEER2 R-32 air conditioner with a high-efficiency 96% AFUE gas furnace for strong heating performance and efficient cooling.
Q: What is the furnace heating capacity?
A: The furnace is rated at 60,000 BTU input, delivering about 57,600 BTU of usable heat at 96% efficiency.
Q: Does this system use R-32 refrigerant?
A: Yes. The outdoor condenser uses R-32 refrigerant, designed for lower environmental impact and compliance with modern refrigerant standards.
Q: Is this furnace compatible with upflow installation?
A: Yes. The GR9S960803BN furnace supports both upflow and horizontal configurations, making it flexible for basements, closets, or utility rooms.
Q: What makes the 96% AFUE furnace more efficient?
A: It converts 96% of fuel into usable heat, reducing waste and lowering heating costs compared to standard 80% furnaces.
Q: Can this furnace be converted to propane (LP)?
A: Yes. It is factory-set for natural gas but can be converted to propane using an optional LP conversion kit.
Maintenance Tips
- Replace or clean air filter every 1–3 months to maintain strong airflow, efficiency, and indoor air quality.
- Keep outdoor condenser unit clean and free of debris, ensuring at least 2 feet of clearance for airflow.
- Schedule professional HVAC maintenance twice per year for heating and cooling system optimization.
- Inspect and clean supply and return vents regularly to maintain balanced airflow and comfort.
- Check condensate drain system periodically to prevent clogs, leaks, and water damage.
- Verify thermostat operation and settings to ensure accurate temperature control and energy savings.
- Monitor for unusual noises, odors, or performance drops and address issues promptly.
- Have a licensed technician inspect burners, heat exchanger, venting, and safety controls annually.
- Ensure refrigerant levels and electrical connections are checked for reliable cooling performance.
- Improve home insulation and seal air leaks to reduce system workload and increase efficiency.