GOODMAN 2 Ton 13.4 SEER2 80% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9T800603BN
GOODMAN 2 Ton 13.4 SEER2 80% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9T800603BN
Couldn't load pickup availability
GOODMAN 2 Ton 13.4 SEER2 80% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9T800603BN
GOODMAN 2 Ton 13.4 SEER2 80% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GR9T800603BN
The ACiQ AQ-GLXS3BN2410 is a durable, high-quality condenser unit that is the perfect cooling solution for homes up to 1400 square feet in northern states. At a capacity of 2 tons and a SEER2 rating of 13.4, this cooling-only condenser won’t break the bank while still reliably cooling your home for years to come. Easy to access service valves make installation by a licensed HVAC professional a breeze. Pay for high-end performance without the high-end price tag when you choose ACiQ.
Features
- 13.4 SEER2, 2 tons AC-only Condenser: With a 13.4 SEER2 efficiency rating and a tonnage of 2, this AC condenser is a great choice for smaller homes that experience shorter, milder summers.
- Single Stage: When properly sized and installed, a single stage condenser is a cost-effective and durable option to cool your home.
- R32 Refrigerant: With R32 refrigerant, this unit complies with Clean Air Act refrigerant requirements.
- Fully Charged for up to 15' of Line Set: The condenser comes fully pre-charged with enough refrigerant for up to 15 feet of line set.
Manual
- GLXS3B Specifications
- Installation Manual
- Warranty Information
-
CAPFA Specifications Sheet
- GR9T80 Specifications Sheet
- GR9T80 Installation Manual
What our Experts Think
- Reliable All-Season Comfort System: Combines a 2-ton R32 air conditioner with a 60,000 BTU Goodman gas furnace, delivering consistent heating and cooling for compact residential spaces.
- Efficient Cooling Performance: The 13.4 SEER2 rating provides dependable energy efficiency for everyday cooling needs without unnecessary complexity.
- Strong Heating Output for Size: The 60,000 BTU, 80% AFUE furnace offers robust heating capacity, making it suitable for colder environments or higher demand homes.
- Modern R32 Refrigerant Technology: Uses R32 refrigerant, improving efficiency potential while reducing environmental impact compared to older refrigerants.
- Upflow Installation Ready: Designed for vertical airflow (upflow) setups, ideal for basements, closets, utility rooms, and standard HVAC configurations.
- Durable Goodman Engineering: Built for long-term reliability, straightforward servicing, and consistent seasonal performance.
- Value-Oriented Performance System: Focuses on strong heating capability and dependable cooling at a competitive price point.
Q&A
Q: What size home is this Goodman 2 Ton HVAC system best suited for?
A: A 2-ton system is typically designed for small to medium homes, depending on insulation, climate, and layout. Proper Manual J load calculation is recommended for accurate sizing.
Q: What efficiency ratings does this system offer?
A: This system combines a 13.4 SEER2 R-32 air conditioner with an 80% AFUE gas furnace, delivering balanced cooling efficiency and standard gas heating performance.
Q: What is the furnace heating capacity?
A: The furnace is rated at 60,000 BTU input, producing about 48,000 BTU of usable heat at 80% efficiency.
Q: Does this system use R-32 refrigerant?
A: Yes. The outdoor condenser uses R-32 refrigerant, a modern low-GWP refrigerant designed for improved environmental performance.
Q: Is this system compatible with upflow installation?
A: Yes. The GR9T800603BN furnace supports upflow and horizontal installation, making it flexible for basements, closets, and utility spaces.
Q: What blower motor does it use?
A: It includes a 9-speed ECM blower motor that improves airflow control, efficiency, and quieter operation compared to standard motors.
Q: Can this furnace be converted to propane (LP)?
A: Yes. It ships configured for natural gas but can be converted to propane using an optional conversion kit.
Q: Why choose a Goodman HVAC system?
A: Goodman systems are widely used for their value-focused pricing, simple serviceability, and readily available replacement parts when properly installed and sized.
Maintenance Tips
- Replace or clean air filter every 1–3 months to maintain airflow, efficiency, and indoor air quality.
- Keep outdoor condenser unit clear of debris and maintain at least 2 feet of clearance for proper airflow.
- Schedule professional HVAC maintenance twice yearly—before cooling and heating seasons.
- Inspect and clean supply and return vents regularly to ensure balanced airflow and comfort.
- Check condensate drain line periodically to prevent clogs, leaks, and water damage.
- Verify thermostat operation and settings for accurate temperature control and energy savings.
- Monitor for unusual noises, odors, or performance changes and address issues early.
- Have a licensed technician inspect burners, heat exchanger, venting, and safety controls annually.
- Ensure refrigerant charge and electrical components are checked for optimal system performance.
- Improve home insulation and seal air leaks to reduce system strain and boost efficiency.