GOODMAN 2 Ton 13.4 SEER2 80% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GM9S800604BN
GOODMAN 2 Ton 13.4 SEER2 80% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GM9S800604BN
Couldn't load pickup availability
GOODMAN 2 Ton 13.4 SEER2 80% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GM9S800604BN
GOODMAN 2 Ton 13.4 SEER2 80% AFUE 60,000 BTU Gas Furnace and R32 Air Conditioner System - Upflow - AQ-GM9S800604BN
The ACiQ AQ-GLXS3BN2410 is a durable, high-quality condenser unit that is the perfect cooling solution for homes up to 1400 square feet in northern states. At a capacity of 2 tons and a SEER2 rating of 13.4, this cooling-only condenser won’t break the bank while still reliably cooling your home for years to come. Easy to access service valves make installation by a licensed HVAC professional a breeze. Pay for high-end performance without the high-end price tag when you choose ACiQ.
Features
- 13.4 SEER2, 2 tons AC-only Condenser: With a 13.4 SEER2 efficiency rating and a tonnage of 2, this AC condenser is a great choice for smaller homes that experience shorter, milder summers.
- Single Stage: When properly sized and installed, a single stage condenser is a cost-effective and durable option to cool your home.
- R32 Refrigerant: With R32 refrigerant, this unit complies with Clean Air Act refrigerant requirements.
- Fully Charged for up to 15' of Line Set: The condenser comes fully pre-charged with enough refrigerant for up to 15 feet of line set.
What our Experts Think
- Compact High-Output Comfort System: Pairs a 2-ton R32 air conditioner with a 60,000 BTU Goodman gas furnace, delivering strong heating capacity in a smaller cooling footprint.
- Efficient Cooling Performance: The 13.4 SEER2 rating provides reliable, cost-effective cooling for small homes or tightly zoned spaces.
- Powerful Heating for Its Size: The 60,000 BTU, 80% AFUE furnace offers higher-than-average heating capacity for a 2-ton system, ideal for colder conditions or higher heat demand.
- Modern R32 Refrigerant: Uses R32 refrigerant, supporting improved energy efficiency potential and reduced environmental impact compared to older refrigerants.
- Upflow Installation Design: Built for vertical (upflow) setups, making it suitable for basements, closets, and standard HVAC installations.
- Performance-Focused Value Choice: Prioritizes heating strength and dependable operation over premium cooling efficiency.
Q&A
Q: What size home is this Goodman 2 Ton HVAC system best suited for?
A: A 2-ton system is typically designed for small to medium homes, depending on insulation levels, climate zone, and layout. Proper Manual J load calculation is recommended for accurate sizing.
Q: What efficiency ratings does this system offer?
A: This system combines a 13.4 SEER2 R-32 air conditioner with an 80% AFUE gas furnace, delivering reliable cooling performance and standard-efficiency heating.
Q: What is the furnace heating capacity?
A: The furnace is rated at 60,000 BTU input, producing about 48,000 BTU of usable heat at 80% efficiency.
Q: Does this system use R-32 refrigerant?
A: Yes. The condenser uses R-32 refrigerant, a modern low-GWP refrigerant designed for improved environmental performance and compliance with updated standards.
Q: Is this furnace compatible with upflow installation?
A: Yes. The GM9S800604BN furnace is designed for upflow and horizontal installation, making it suitable for basements, closets, and utility spaces.
Q: What blower motor does it use?
A: It includes a 9-speed ECM blower motor that improves airflow control, energy efficiency, and quiet operation compared to traditional single-speed motors.
Q: Can this furnace be converted to propane (LP)?
A: Yes. It ships configured for natural gas but can be converted to propane using an optional LP conversion kit.
Q: Why choose a Goodman HVAC system?
A: Goodman systems are widely used for their strong value, simple serviceability, and readily available replacement parts when properly installed and size
Maintenance Tips
- Replace or clean air filter every 1–3 months to maintain airflow, efficiency, and air quality.
- Keep outdoor condenser unit clear of debris with at least 2 feet of clearance for proper operation.
- Schedule professional HVAC maintenance twice yearly (cooling and heating seasons).
- Clean and inspect supply/return vents regularly to ensure balanced airflow and comfort.
- Check condensate drain line periodically to prevent clogs, leaks, and water damage.
- Verify thermostat settings and operation for accurate temperature control and energy savings.
- Address unusual noises, odors, or performance changes early to prevent costly repairs.
- Have a licensed technician inspect burners, heat exchanger, venting, and safety controls annually.
- Ensure refrigerant levels and electrical components are checked for efficient performance.
- Maintain proper insulation and seal air leaks to reduce system strain and improve efficiency.