The Wilkins 2-975XL2 is a 2-inch Reduced Pressure Principle (RPZ) backflow preventer engineered for high-hazard potable water protection. Its compact wye-pattern bronze body provides short lay length and in-line service access to the checks and relief valve for faster maintenance.
Documentation and repair parts are available; recommended for commercial, irrigation, and high-hazard potable water systems requiring RPZ protection. Follow local codes for testing and installation requirements.
Features
- Lead‑free construction compliant with low‑lead plumbing laws (0.25% weighted average).
- Cast bronze body (ASTM B584) with stainless steel fasteners and Noryl seats for corrosion resistance.
- Female NPT (FNPT) x FNPT threaded ends with full-port quarter‑turn (QT) ball valves included for shutoff and service.
- 175 PSI pressure rating, 180°F temperature rating, and 350 PSI hydrostatic test rating.
- Short end‑to‑end distance (26-1/2") eases replacement and installation in constrained spaces.
- Meets ASSE 1013, AWWA C511, NSF/ANSI 61, CSA and IAPMO/CUPC listings for potable water applications.
- Wye-pattern design allows separate access to each check and the relief valve to reduce labor and repair time.
What our Experts Think
- Maximum protection RPZ design: Provides industry-leading defense against both back-siphonage and backpressure contamination in drinking water systems.
- Heavy-duty bronze construction: Built with corrosion-resistant materials for long service life in demanding environments and continuous flow applications.
- Service-friendly wye pattern body: Separate access to checks and relief valve allows faster in-line maintenance and reduced downtime.
- Lead-free potable water compliance: Meets modern low-lead plumbing regulations for safe use on municipal and building water supplies.
- Integrated shutoff flexibility: Includes FNPT connections with full-port service valves for easier installation and system isolation.
- Built for code-heavy installations: Commonly used in high-risk applications such as commercial buildings, fire systems, and irrigation tie-ins where RPZ protection is required.
Q&A
Q: What is the Zurn Wilkins 2-975XL2 used for?
A: A 2" lead-free reduced-pressure zone (RPZ) backflow preventer designed for high-hazard applications, protecting potable water systems from contamination caused by backpressure or backsiphonage.
Q: Is it safe for drinking water systems?
A: Yes. It is lead-free compliant and certified to NSF/ANSI 61 and ASSE 1013 standards for potable water protection.
Q: What level of protection does it provide?
A: High-hazard protection using a reduced-pressure zone assembly with two check valves and a relief valve that discharges when unsafe pressure conditions occur.
Q: What size and connections does it have?
A: 2-inch FNPT threaded inlet and outlet connections, designed for commercial and irrigation piping systems.
Q: What materials is it made from?
A: Lead-free cast bronze body with corrosion-resistant internal components for durability and long service life.
Q: Can it be installed in different orientations?
A: Yes. It supports horizontal or vertical installation (depending on flow direction and code requirements).
Q: What are its operating limits?
A: Typically rated up to 175 PSI working pressure and about 180°F maximum temperature.
Maintenance Tips
- Schedule annual certified testing to ensure reliable backflow protection and code compliance.
- Inspect regularly for leaks, relief valve discharge, and corrosion, especially after pressure fluctuations.
- Keep test cocks, shutoff valves, and internal passages clean to prevent debris-related malfunction.
- Flush the assembly after installation or service to reduce sediment buildup.
- Protect from freezing temperatures using insulation or seasonal winterization where needed.
- Use only genuine repair parts from Zurn Wilkins to maintain certification and performance.
- After servicing, always re-test before returning the unit to service.